EasyManua.ls Logo

Philips 42PFL3704D/F7 - Inverter Power CBA Bottom View

Philips 42PFL3704D/F7
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-26
BA94H0F01033-A
Inverter Power CBA Bottom View [42PFL3704D/F7 (Serial No. : DS1A**********, YA2A**********)]
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 8A, 250V fuse.
CAUTION ! :
ATTENTION : Utiliser un fusible de rechange de même type de 8A, 250V.
8A 250V