EasyManua.ls Logo

Philips BVP528 BV User Manual

Philips BVP528 BV
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BVP528 HGB
BVP528 BV
BVP518 HGB
BVP518 BV
220 V
400 V
OptiVision LED gen3.5
BVP528/BVP518
1 RG1
*Lumen maintenance at median useful life 50Khrs is L80
© 07/2020 Signify Holding. All rights reserved
Any modication on the luminaire will cancel the warranty
SCx
Performance is not guaranteed for rated NOMINAL mains voltage of below 220Vac and over 400Vac.
Tolerance for voltage uctuations: safety ±10%, performance -8/+6%, is part of the design and as per standard EN 62384.
1/24
Printed in Spain
Data subject to change without notice
Keep for future reference: www.philips.com/lighting
443000021241_A
HGB BV 90º HGB
BVP528 33 26,5 0,47
BVP518 29 22 0,33
Conguration 15º 30º 40º 50º 65º 90º
BVP518 HGB 0,18 0,22 0,25 0,27 0,27 0,29 0,33
BVP518 HGB+ EXTERNAL LOUVER 0,23 0,25 0,27 0,26 0,25 0,25 0,32
BVP518 BV 0,10 0,17 0,21 0,24 0,26 0,30 0,34
BVP518 BV+EXTERNAL LOUVER 0,13 0,18 0,22 0,25 0,25 0,26 0,32
BVP528 BV 0,12 0,20 0,29 0,33 0,33 0,41 0,48
BVP528 BV+EXTERNAL LOUVER 0,14 0,24 0,29 0,31 0,34 0,38 0,44
BVP528 HGB 0,20 0,27 0,30 0,32 0,33 0,41 0,47
BVP528 HGB+EXTERNAL LOUVER 0,23 0,30 0,32 0,32 0,34 0,39 0,44
OPERATING
TEMPERATURE
MAX.
MIN.
OUTDOOR 45ºC -40ºC
INDOOR 45ºC -40ºC
Question and Answer IconNeed help?

Do you have a question about the Philips BVP528 BV and is the answer not in the manual?

Philips BVP528 BV Specifications

General IconGeneral
BrandPhilips
ModelBVP528 BV
CategoryLighting Equipment
LanguageEnglish

Summary

Mounting Positions Allowed

Mounting Positions Not Allowed

Luminaire Cleaning

Cleaning Techniques and Materials

Luminaire Accessories

External Louvres for Luminaires

Details on installing external louvres for luminaires, specifying quantities per module.

Precision Aiming Device

Information on the precision aiming device, specifically for aiming without a visor.

Changing Luminaire from BV to HGB

Driver Box Features

Driver Box Distances and Placement

EVP500 DALI Electrical Connection (L < 50m)

Special Request Electrical Connection (L < 50m)

Wiring Connection Box (L < 50m)

Electrical Connection (50m < L < 200m)

Driver Box Installation on Cabinet

Driver Box Orientation

Specifies the required vertical position for driver boxes within a cabinet.

Driver Box Distances

Details the minimum required distances between driver boxes and walls or other boxes.

Driver Box Temperatures

Outlines maximum relative humidity and operating temperature guidelines for driver boxes.

Driver Box Installation in Mast

Driver Box Installation on Bracket or Horizontal

Luminaire Circuit Breaker Capacity

Annex I: EU Declaration of Conformity

Signify Holding Declaration

Declaration by Signify Holding regarding radio equipment compliance with EU directives.

Related product manuals