1.4. Restore the Dynamic Stroke Version
It is important to restore the Dynamic Stroke version of the set before returning the repaired set back to the customer.
Restoring this stroke version will ensure that the set is correctly set for the region.
Follow the steps below to change dynamic stroke versions:
Close DVD tray with no disc
Enter the following RC sequence:
<3> <4> <8> <0> <0> <5> <OK> for /05
<3> <4> <8> <0> <3> <1> <OK> for /31
<3> <4> <8> <0> <5> <1> <OK> for /51
<3> <4> <8> <0> <5> <8> <OK> for /58
While entering the RC sequence, the VFD will display the entered keys
The VFD will display “WRNGSTRK” if the incorrect sequence is entered.
If the correct RC sequence is entered and <OK> is pressed the VFD will dispaly “Stroke Version Changed to /YY”
Press standby button to go to standby mode or power off the mains to complete the process.
Note:It is essential to standby or power off the set for the stroke version restoration to take effect. The set will then start in
the Virgin Mode.