EasyManua.ls Logo

Philips GC 3006 - Disassembly Advice; Dial and Inlay Removal; Handle and Dosing Unit Removal; Tank and Thermostat Bush Removal

Philips GC 3006
5 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DISASSEMBLY ADVICE IRON
DIAL 1
BACKPLATE 2
CORD SET 3
SWIVEL 4
Remove Screw A (1x)
Remove BACKPLATE 2
Remove Screw B (2x)
cord clamping
INLAY 5
LAMP ASSY 6
FILLING DOOR 7
STEAM SLIDER 8
LAMP COVER 9
SOS KNOB 10
SPRAY KNOB 11
TANK SEAL 12
remove Screw A (1x)
remove BACKPLATE 2
remove Screw B (2x)
cord clamping
remove INLAY 5
DOSING UNIT 13
remove Screw A (1x)
remove BACKPLATE 2
remove Screw B (2x)
cord clamping
remove INLAY 5
remove Screw C (2x)
remove Screw D (2x)
remove DOSING UNIT 13
HANDLE 14
RATTLE SPRING 15
PUMP 16
remove Screw A (1x)
remove BACKPLATE 2
remove Screw B (2x)
cord clamping
remove INLAY 5
remove Screw C (2x)
remove Screw D (2x)
remove DOSING UNIT 13
remove Screw E (2x)
remove HANDLE 14
TANK 17
THERMOSTAT
BUSH 18
remove Screw A (1x)
remove BACKPLATE 2
remove Screw B (2x)
cord clamping
remove INLAY 5
remove Screw C (2x)
remove Screw D (2x)
remove DOSING UNIT 13
remove Screw E (2x)
remove HANDLE 14
remove Screw F (2x)
remove TANK 17
SHIELD 19
remove Screw A (1x)
remove BACKPLATE 2
remove Screw B (2x)
cord clamping
remove INLAY 5
remove Screw C (2x)
remove Screw D (2x)
remove DOSING UNIT 13
remove Screw E (2x)
remove HANDLE 14
remove Screw F (2x)
remove TANK 17
remove Screw G (1x)
remove SHIELD 19
COVER 20
SOS SEAL 21
DOSING SEAL 22
SOLEPLATE ASSY 23
remove Screw A (1x)
remove BACKPLATE 2
remove Screw B (2x)
cord clamping
remove INLAY 5
remove Screw C (2x)
remove Screw D (2x)
remove DOSING UNIT 13
remove Screw E (2x)
remove HANDLE 14
remove Screw F (2x)
remove TANK 17
remove Screw G (1x)
remove SHIELD 19
remove Screw H (2x)
remove COVER 20

Related product manuals