FAILURES WHEN SWITCHING ON THE APPLIANCE
Problem description /
“Error” message displayed
Actions to perform Hints/tips/solution
1. MESSAGE
No WATER !
-Fill watertank-
Fill tank with water.
Check function of the Reed sensor
(no magnet, open contact = >>> Ω,
magnet closed contact = 0 Ω)
• Check if lled tank is inserted correctly.
Check presence of Magnet in tank or see if
it is jammed.
For testing purposes short circuit jumper
(J7) display message will disappear.
Exchange Reed sensor.
2. MESSAGE
HEATING UP
PLEASE WAIT...
After ± 6 minutes
GENERIC ALARM !
Check if Coffee heater is heating up. Check voltage is present on connectors
(F1) & (F6) (if not exchange PCB)
Check Fuse/TCO became defect (2x)
(exchange when defect)
Check resistant of heating element.
(45 - 55 Ω) (exchange when defect)
If coffee heating element is heating up
check function/circuit of NTC coffee
heater. (J5) PCB.
3. MESSAGE
INSERT BREWING
UNIT !
Place brewing unit.
Check the function and circuit of micro
switch (M1).
Check if the micro switch mechanical will
be activated if the brewing unit is properly
placed and the brewing unit is in top
position.
Exchange micro switch. (M1).
4. MESSAGE
Flushing…
After 20 – 30 seconds
‘GROUND TOO
FINE! –Adjust mill’
and ‘OPEN STEAM
KNOB!
When water is pumped through the
system, the fl ow meter measures the
pumped volume. When the system detects
a mismatch in expected and measured
volume the failure will be displayed.
Check if the pump is pumping.
• Check the ow meter and it’s circuit is
functioning.
Check if water is present in the water
container and the water container has
been correctly placed. See if water is
visible in the area container - pump.
Check if the pre fi lter not became clogged
by particles.
Check if voltage is during pumping
present on connectors (F2) & (F10).
(if not exchange PCB)
Check if voltage is during pumping
present on the pump.
(if not check the TCO on the pump,
exchange when defect)
• Exchange pump.
Exchange Flow meter.
TROUBLE SHOOTING