HD5720/30
12-23
TROUBLE SHOOTING
Technical related problems.
Warning:
Live Voltage is applied to the micro switches used in the appliance!!!!!
Always disconnect plug from the mains when repairing!
When the appliance generates a GENERIC ALARM message, the only way to reset this is
by unplugging the power plug from the mains.
FAILURES AT PLUGGING IN APPLIANCE
Problem description /
“Error” message displayed
Actions to perform Hints/tips/solution
1. Appliances doesnt work
at all.
Check if main voltage is applied on the main
PCB (vertical PCB on the right side) by
measuring the voltage (220 - 230 V) on the
connector F3 and F4.
(see electrical drawing scheme)
If no voltage is present:
check power cord and connections!
If voltage is present, check all electrical
connections on the PCB, otherwise exchange
PCB.
2. MESSAGE
GENERIC ALARM !
• Check micro switch (M1) top position
brewing unit and it’s circuit.
• Check NTC sensor (J5) heater and it’s
circuit.
• Check Hall sensor (J3B) motor lift and it’s
circuit.
Micro switch is NC (normally closed)
(exchange switch)
Value NTC resistor at 23 °C ± 110 kΩ
± 95 °C = 5.3 kΩ
Value measured on PCB J5
(without NTC) ± 10 kΩ
If the GENERIC ALARM message
appears after the brewing unit went down,
most probably the Hall sensor/connections
is the problem.
(counting of pulses starts after actuating
the brewing unit_down_position M2, so
going up direction!)
3. MESSAGE
PLEASE WAIT......
If a normal motor sound of the brewing
unit lift is noticed, but the brewing unit
doesnt move, check the driving belt.
If a motor sound is noticed and afterwards
you hear a hard noise sounding like a
blocked motor and the brewing unit stays
at bottom position, check the micro switch
(M2) bottom position brewing unit and it’s
circuit.
If no motor sound is noticed, check the
wire connection of the motor and see if
voltage has been applied on the motor side.
If no motor sound is noticed and also no
voltage has been measured on pins F7 &
F8 PCB probably the 2 relays on the main
PCB became defect.
Belt broken, replace belt.
Replace micro switch (M2).
If voltage on the motor circuit board has
been applied, motor is probably defect.
Exchange total brewing unit lift assy.
Exchange main PCB
4. MESSAGE
CLOSE DOOR !
Close the service door.
Check the function and circuit of micro
switch (M4).
Check if the micro switch mechanical will
be activated if the door is closed.
Exchange micro switch. (M4).
5. MESSAGE
INSERT WASTE BIN !
Place waste bin.
Check the function and circuit of micro
switch (M3).
Check if the micro switch mechanical will
be activated if the waste bin is placed.
Exchange micro switch. (M3).
!