Vacuum cleaner
HR 8514
HR 8532
HR 8536
HR 8539
Philips Domestic Appliances and Personal Care
PRODUCT INFORMATION
Maximum air displacement : 32 I/sec
Maximum vacuum water column : 240 cm
Power consumption (IEC) : 1200 W
Dust storage capacity : 3 l
Cord length (depends on version) : 6 or 8.5 metres
Filter system : Paper dustbag
: Motor inlet filter
: Exhaust air filter
Dimensions cleaner : 44.5 x 29.5 x 25 cm
Weight cleaner : 5.5 kg
OPTIONAL
Exhaust air filter HR 6932 = 4822 015 70056
Sydney cotton dustbag HR 6997 = 4822 480 10115
Sydney paper dustbag HR 6998 = 4822 480 10114
Sydney closable pap.dustbag HR 6999 = 4822 480 10113
Turbo brush HR 6988 = 4822 479 20196
SERVICE INFORMATION
To open the appliance, first remove the control panel (item 11)
with a big screw driver to disconnect the 2 snap locks (see
drawing).
Component configuration on exploded view may differ in case of
specific versions. However, the actual components are
distinguished bij means of code numbers.
If a repair has been made, make sure that all functions of the
appliance are working correctly.
The spare parts have been standardized as much as possible.
Item 6, cotton dustbag, is used in those countries where paper
dustbags are not available.
Item 21 is provided with a long cord-winder spring; both long and
short cords can be used in combination with this spring.
Items 37,38 and 39 can be used if the version is provided with an
electrically switched park assist.
Item 71 up to and including item 80. The assembly of accessories
depends on the national version.
To connect the nozzle, the telescopic tube and the handle:
insert the narrowed section into the wider section while
turning it a little (fig. 1). To disconnect: pull while rotating.
To adjust the telescopic tube (item 74) to the required length,
pull the locking knob in the direction of the arrow (fig. 2) while
sliding the top section of the telescopic tube into or outof the
lower section.
To (dis)assemble the appliance use TORX screw driver no T15
= 4822 395 10329, which is one of a set consisting of T20, T15,
TI0, T9, T8, T7 and T6 = 4822 395 50145.
Depending on the original length of the cord, the spare cord must
be shortened.
Adjusting the PCB on the motor to 220V, 60Hz.
1. Make sure that the potentiometer (item 36) is set at min.
position.
2. Adjust the potentiometer on the PCB item 45, on the motor to
220V/60Hz to allow the motor to run smoothly.
Please note: the standard setting of the spare PCB is
230V/50Hz.
There are open-circuit voltages on all wires.
MSH coding: 8838 514 00000 ( sahara yellow )
8838 532 00000 ( racing green )
8838 536 00000 ( blue purple )
8838 539 00000 ( california white )
4822 729 21766
97/04
PCS 88 357
PublishedbyPhilipsDomesticAppliancesandPersonalCare PrintedintheNetherlands
©
Copyrightreserved Subjecttomodification
fig. 1
fig. 2
!
Service
Information

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Philips HR 8514 and is the answer not in the manual?

Philips HR 8514 Specifications

General IconGeneral
BrandPhilips
ModelHR 8514
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals