7
EN
English
Water level
When there is not enough water in the water
tank, the appliance will work in the following
ways.
The water level drops and the red
indicator light starts blinking (g. h).
The humidier continues to work for
30 minutes and then stops working, the
red indicator light remains on.
The appliance will resume work when you rell
water into the water tank.
Note
If the water tank is empty when the humidier is
plugged in and switched on, the red indicator
light blinks for 2 minutes and then remains on
before the water tank is relled with water.
It is normal to nd some water left in the tank.
Rellingwater
Water level can be observed through the
transparent water tank window.
1 Switch off the humidier and unplug it.
2 Remove the upper unit by holding it at
both sides (g. b).
3 Fill the water tank with cold tap water
until water reaches the maximum water
indication level (g. f).
Note
When lling water, do not exceed the maximum
water level, or water might leak from the drain
hole and air inlets.
Do not shake the water tank when moving it,
or water might leak from the drain hole and air
inlets.
Do not ll water through the air outlets on top
of the humidier.
4 Place the upper unit back onto the water
tank.
Setting the humidity level
Note
Make sure that the water tank is lled with
water before the humidier can function (see
the chapter 'Getting started', section 'Prepare
for humidication').
The humidier will turn on at intervals, in order
to ventilate air around humidity sensor, therefore
get more accurate reading on environment
humidity. This setting applies to the humidity
level setting, including the Auto mode.
1 Press the humidity button once or
more times to set the desired air humidity
to 40RH%, 50RH% or 60RH% (g. m).
» The humidity light (40, 50 or 60) of the
humidity level goes on.
» The humidity indicator light is red if the
desired humidity level is not reached.
The light turns blue when the desired
humidity level is reached.
Tip
A comfortable humidity level is from 40RH% to
60RH%. You can choose the preferred humidity
level at 40%RH, 50%RH or 60%RH..
Note
If no preset humidity level is selected, the
humidity indication light will be off.