Service Manual
Philips Domestic Appliances and Personal Care
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
Innergize
HB945
06/09
PRODUCT INFORMATION
- This full-body tanning appliance is equipped with an
electronic power supply. This means that when the
appliance is connected to the mains, the tanning or
relaxing functions are made visible by means of symbols
on the display. The set time is also shown on the display.
During the last minute of the set time, an accoustic
signal sounds.
- The UV lamps only burn in combination with the IR
(relax) lamps. When the UV lamps are on the IR lamps
burn at reduced intensity.
- The IR lamps can also be used separately at full intensity
for a relax session.
- This appliance is equipped with a sound module,
offering a selection of four nature sounds. The user can
also connect an external music appliance to play his/her
own music, either via the loudspeakers or the earphones.
- This tanning appliance has also been fitted with a scent
unit. The scent granules required for this unit can be
ordered as service part (see parts list).
IMPORTANT
- Because of the brief high starting voltage, the appliance
should be connected to a circuit protected with a 16A fuse.
- HPA lamps only go on at a restart if they have cooled down
sufficiently.
- Never touch the HPA lamps with your fingers. If necessary,
clean the lamps with a cloth moistened with some alcohol.
- When a new HPA lamp is installed, this lamp may have
a different colour compared to the other lamp. This is
normal and will disappear after a short period of use.
- After repair, the glass filters should be free from fingerprints.
If necessary clean the filters with some alcohol.
- Never look directly into the light of an HPA lamp when it
is on without protective goggles.
- Insufficient cooling – for instance when the vents are
blocked or when the fan has broken down – will cause the
thermal safety cut-out to switch the appliance off. Once the
cause of overheating has been removed and the appliance
has cooled down sufficiently, it will switch automatically on
again.
- Let the appliance cool down for 15 minutes before folding
it back into transport position and storing it.
- Only move the appliance when it is in transport position,
i.e. when it is folded.
- If there are complaints about inadequate tanning, the
output of the lamps can be measured with a UV-X 36
meter. For the minimum values, see table under ‘Technical
information’.
Question and Answer IconNeed help?

Do you have a question about the Philips Innergize HB945 and is the answer not in the manual?

Summary

Disassembly and Repair Instructions

Replacing Lamps, Fans, and Starters

Instructions for replacing the appliance's lamps, fans, and starters.

Replacing Lock Grips, Soundboard, Relay Board, and Power SMPS

Procedure for replacing lock grips, soundboard, relay board, and power SMPS (PCB).

Replacing Timer Front, Speakers, and Display

Steps to replace the timer front assembly, including speakers and display.

Replacing Seesaws

Guidance on replacing both seesaw components, as they should always be replaced together.

Stand Assembly Information

Details about the appliance's stand, including its hydraulic press mounting.

Resetting Timer and Hour Counter

Instructions for resetting the timer and hour counter, particularly after lamp replacement.

Philips Innergize HB945 Specifications

General IconGeneral
BrandPhilips
CategoryLantern
TimerYes
ReflectorYes
ColorWhite
ModelInnergize HB945

Related product manuals