- 2 -
Navigating the Provider Mode Screens
To navigate these display screens:
Turn the control wheel to toggle between options and settings on the screen. Press the control wheel to choose an option
or setting that is highlighted. If you choose “Back” on any screen, it will take you back to the previous screen.
Note: Choosing “EXIT” from the Provider screen will exit provider mode and the device will return to the Home screen
in the patient mode.
Note: Provider mode will time out after 1 minute of inactivity and automatically exit the provider mode and return to the
Home screen in the patient mode.
Provider Mode Screen Descriptions
The following sections will describe the options available under the 3 choices from the Provider screen (Reminder, Setup, and Info).
Reminder Screen
From the Provider screen, highlight “Reminder” and press the control wheel. The following Reminder screen will appear.
Back
Reminder off 30 90
180 270 365
Reminder
Reminder Screen
• Reminder - You can set a reminder on this screen that will let patients know when it is time to perform a certain task,
such as replacing the mask. You can select one of the following settings: Off (no reminder is set), or you can set the device
to display a reminder after 90, 180, 270, or 365 days.
Note: You can set a specic patient reminder message using the EncorePro software, and put this message on the SD card
or send it to the patient’s device via a modem.
Setup Screen
From the Provider screen, highlight “Setup” and press the control wheel. The following Setup screen will appear.
Back
Mode Auto CPAP
Auto max (auto min) - 20.0
Auto min 4.0 - (auto max)
CPAP pres 4.0 - 20.0
Flex type C-Flex (C-Flex+)or(A-Flex) None
Flex 1 2 3
Ramp time 0:00 - 0:45
Ramp start 4.0 - (auto min)or(CPAP pres)
Tubing type lock on o
Tubing type 15 22 15H
SYSTEM ONE resistance 0 X1 X2 X3 X4 X5
Lock SYSTEM ONE on o
Heated Tube humidication on o
SYSTEM ONE humidication on o
Humidier 0 1 2 3 4 5
Humidity level 1 2 3
Tube temperature 0 1 2 3 4 5
Auto on on o
Auto o on o
Mask alert on o
Mask t check on o
Humidier LED Backlight on o
Show AHI/leak/PB on o
Split night on o
Split night start
Silent mode on o
Language EN ES
Back
Setup
Setup Screen
Note: The screen will only show a few lines at a time. As you rotate the control wheel to toggle over different options
the screen will slide up and down accordingly. If the text is too long to completely t on the screen, it will scroll
horizontally across the screen when highlighted.