Control Mode : Knob + Button
Rated Power : 48W
Input : 24 VCD
Product Dimension : L27.7 x W20.7 x H46.7 cm
Specifications
Washing Bucket Volume : 8 L
Maximum Model Size : L21.8 x W12.3 x H23.5 cm
Weight : 3.5 kg
Timer : 0 - 30 minutes
Before You Start
01
Place the machine on a clean and level surface.
Put the washing basket into the bucket.
Please make sure to wear protective goggles, gloves, masks, and long-sleeved clothing when handling the machine.
Pour in an appropriate amount of alcohol
(95%) or other cleaning fluid (Phrozen Wash).
Cover the bucket when the machine is in use to avoid splashing and objects falling.
Keep the bucket covered to avoid alcohol evaporation when the machine is not in use.
Instructions
02
After printing is completed hang the building plate with prints on the cleaning basket (if the building
plate is smaller than 7”, use the basket holder). For building plate over 10” put the prints straight into
the cleaning basket.
Turn the knob to adjust the time and press to set. It is recommended that each cleaning time should not
exceed 30 seconds as overcleaning might damage the prints.
After the timer stops, lift the basket vertically and take out the prints.
Leave prints to dry or use an air gun to accelerate the drying process.
For hollow and more complicated models, please make sure the prints are clean. If any residual resin was
found, repeat steps 2-5.
After the cleaning process is completed, put prints into the curing machine to cure.
1
2
3
4
5
6
Warning
Please disconnect the power before cleaning or replacing alcohol (cleaning fluid).
DO NOT pour resins or other liquid except alcohol (cleaning fluid) into the cleaning bucket.
Avoid direct contact with skin to prevent allergies.
In case of contact with resin and alcohol (cleaning fluid), please rinse immediately with plenty of water.
DO NOT remove prints from the bucket when the machine is running.
Washing Bucket
Washing Basket
Holder
Washing Basket
Timer Display
Display the remaining
cleaning time.
Setting Knob
Set TimeTurn the knob to
adjust the time and press it to
set.
PauseWhen the machine is
running, press the knob to
pause.
Reset TimerLong press the
knob to reset the timer.
Note : Regularly replace 95% alcohol (cleaning fluid) for optimum results.
Scan for other
languages
InstagramYouTubeHelp Center Facebook
Phrozen Wash & Cure Kit User Guide
Washing Station Post Printing Cleaner
A
B
A B
Question and Answer IconNeed help?

Do you have a question about the Phrozen Wash & Cure Kit and is the answer not in the manual?

Phrozen Wash & Cure Kit Specifications

General IconGeneral
BrandPhrozen
ModelWash & Cure Kit
CategoryUltrasonic Jewelry Cleaner
LanguageEnglish

Summary

Washing Station Before You Start

Machine Placement and Preparation

Place the machine on a clean, level surface and prepare the washing basket and bucket.

Personal Protective Equipment

Wear protective goggles, gloves, masks, and long-sleeved clothing when handling the machine.

Adding Cleaning Fluid

Pour an appropriate amount of 95% alcohol or other cleaning fluid into the bucket.

Bucket Cover Usage

Cover the bucket during use to avoid splashing and when not in use to prevent evaporation.

Washing Station Instructions

Placing Prints for Cleaning

Hang building plate with prints on the basket or place directly into the basket.

Setting Cleaning Time and Operation

Adjust timer knob for time, press to set, and avoid over 30 seconds to prevent damage.

Removing and Drying Prints

Lift basket vertically to remove prints, then leave to dry or use an air gun.

Post-Cleaning Curing

After cleaning, place prints into the curing machine to cure.

Fluid Maintenance Note

Note: Regularly replace 95% alcohol for optimum cleaning results.

Washing Station Safety Warnings

Power and Fluid Handling Precautions

Disconnect power before cleaning. Only use alcohol/cleaning fluid. Avoid skin contact.

Emergency Rinse Procedure

In case of contact with resin or alcohol, rinse immediately with plenty of water.

Operational Safety During Use

Do not remove prints from the bucket while the machine is running.

Curing Station Before You Start

Machine Placement and Setup

Place machine on a level surface, install turntable, and connect power.

Protective Gear and Operation

Wear protective goggles and do not lift the acrylic cover during operation.

Curing Station Instructions

Pre-Curing Model Preparation

Ensure models are clean and free of residual resin before placing them for curing.

Model Placement and Cover

Place models on the turntable and securely put the acrylic cover into place.

Selecting Curing Mode and Time

Choose CURE, FAN, or FAN+CURE, then input time up to two hours.

Post-Curing Handling

Remove the model after curing. Note: Models may be hot, handle with care.

Curing Station Safety Warnings

Maintenance and Power Safety

Disconnect power before performing maintenance.

Operation During Curing

Do not take off the acrylic cover while the machine is running.

Skin Contact Precautions

Avoid direct skin contact with resin/cleaning fluid to prevent allergies.

In Case of Contact

If contact occurs with resin/cleaning fluid, rinse immediately with plenty of water.