Regular checks cleaning and maintenance
Operating Manual PSEN sc B 5 Series
1004508-EN-02
63
11.3 Maintenance
Other than cleaning the front panel, the safety laser scanner requires no other form of
maintenance.
CAUTION!
Improper cleaning agents can cause damages to the safety laser scan-
ner.
Malfunctions of the safety laser scanner can occur and the safety function is
no longer guaranteed.
Use only the following cleaning agents.
Moist cotton cloths should be used for cleaning.
Avoid using
} Alcohol,
} Solvents,
} Cloths made of wool,
} Cloths made of synthetic material.
Clean the front panel during the regular
check of the safety laser scanner [ 55].

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PSEN sc B 5.5 and is the answer not in the manual?

Pilz PSEN sc B 5.5 Specifications

General IconGeneral
Operating voltage24 V DC
Scanning range5.5 m
Safety integrity levelSIL 3
Performance levelPL e
ConnectionM12 connector
Protection ratingIP65
Detection capability14 mm
Outputs2 OSSD outputs
Ambient temperature+50 °C