28 English 29English
CHANGING THE TEMPERATURE UNIT [F <-> C]
To change the unit of the displayed temperature (F= Fahrenheit, C= Celsius), the device
must be in a temperature-controlled operating mode. Then, press and hold the (-) button
until the lower limit of the temperature is reached in any temperature unit. Pressing or
continuing to hold the (-) button afterward will automatically switch the displayed
temperature to the upper limit of the other temperature unit.
By holding the (+) button beyond the upper limit [F], the temperature control will be
completely deactivated (OFF).
PUFF-TIME LIMIT
If the re button is pressed for more than 20 seconds, the device will automatically
interrupt the power output to prevent overheating or dry ring of the atomizer.
REVERSE POLARITY PROTECTION
Always ensure the correct orientation of the battery when inserting it into the battery
compartment. If a battery is inserted with the wrong orientation, the integrated reverse
polarity protection prevents damage to the electronics. The device cannot be turned on
or charged in this state.
BATTERY CHARGING
The PIPELINE BOX DNA60 is equipped with a separate PCB, that allows the charging of
an inserted Li-ION battery through the USB-C port. Use only a high-quality and
adequately dimensioned charging cable/power adapter for this purpose (not included).
We recommend using specialized external chargers for charging Li-ION batteries.
Especially for small cell types (e.g., 18500, 18350), their lifespan can be signicantly
increased by using an appropriately lower charging current (≤0.5 C).
ERROR MESSAGES
CHECK ATOMIZER
The device is unable to detect the resistance [Ω] of the attached atomizer/coil.
Please check for dirt or debris on the contact points between the atomizer and the device
and clean them if necessary. Ensure that the atomizer is screwed on ush and that the
positive pole of the atomizer makes contact with the device (adjust if necessary).
Inspect the coil of the atomizer (consider replacing if necessary).
SHORTED
The device detects a short circuit in the attached atomizer.
Please check the isolators of the atomizer. Inspect the coil of the atomizer
(consider replacing if necessary).
WEAK BATTERY
The output voltage of the inserted battery under load is below the set value
(default: 2.8 volts). Insert a charged battery or connect an appropriate charging cable/
power supply to the USB-C port of the device. An unusual frequency of this error message
often indicates a reduced battery capacity due to improper storage, handling, or intensive
use (consider replacing if necessary).
OHMS TOO LOW / OHMS TOO HIGH
The resistance [Ω] of the attached atomizer/coil is outside the allowable range
(0.15 Ω – 3.0 Ω). Check the coil of the atomizer (consider replacing if necessary).