1. WARNINGS AND PRECAUTIONS CONCERNING INSTALLATION
- The appliance must be installed only by qualified personnel and it can be
used only after installation made in accordance with following installation
instructions.
- The appliance must be supplied through a residual current device (RCD)
having a rated residual operating current not exceeding 30mA.
- It is advised to predispose a power socket for the appliance exclusive use.
- If the supply cord is damaged, it must be replaced by the manufacturer or
similarly qualified person.
- During installation and before attempting any work on the unit, the electrical
power supply must be disconnected.
2. OPERATING PRINCIPLE
Geyser is a plastic tank containing a pump able to discharge automatically
through a little pipe (diameter 40mm) up to the nearest sewer, the wastewater
coming from any appliance (bidet, shower, basin, dishwasher machine, lavatory
machine, bath tub, etc.), except for water coming from WC’s. The pump is
activated automatically by a pressure switch controlling the water level inside
the unit.
Geyser can discharge hot water (up to 100°C) and without needing any type of
maintenance.
Fig. 1