Voice, Data and Video Tester
outlined
Coax Type Belden P/N Center + Shield Maximum Length
RG-58A/U 8259 14.9Ω / 1,000 ft 6,710ft (2,045m)
9311 25.8Ω / 1,000ft 3,876ft (1,182m)
7806A 11.8Ω / 1,000ft 8,475ft (2,583m)
RG-59/U 9310 24.1Ω / 1,000ft 4,150ft (1,265m)
9259 23.5Ω / 1,000ft 4,255ft (1,297m)
8241A 49.7Ω / 1,000ft 2,010ft (613m)
9275 78.5Ω / 1,000 1,275ft (389m)
9659 17.6Ω / 1,000ft 5,682ft (1,732m)
RG-6/U 1694A 7.2Ω / 1,000ft 13,889ft (4,234m)
1152A 29.8Ω / 1,000ft 3,360ft (1,025m)
Mini Coax 9221 111Ω / 1,000ft 900ft (275m)
RG-11/U 1523A 15.1Ω / 1,000ft 6,623ft (2,019m)
U
S
A
M
A
D
E
I
N
T
H
E
M
A
D
E
I
N
T
H
E
U
S
A
www.platinumtools.com
©2011 Platinum Tools Inc. All rights reserved. 1/11
®
Instruction Sheet: P/N T119
GENERAL SPECIFICATIONS
The Platinum Tools, VDV MapMaster™ is a portable voice-data-video
cable tester. It tests and troubleshoots RJ11, RJ12, RJ45 and F-conector
terminated cables and provides built-in tone generation for cable tracing.
•Dimensions: 6.4˝ x 2.8˝ x 1.4˝ (16.3 x 7.1 x 3.6 cm)
•Weight: 9.0 oz. (256 grams) with battery and remote
•Operating Temperature: 0˚C/32˚F to 50˚C/122˚F
•Humidity: 10% to 90%, non-condensing
•Maximum Voltage between any two connector pins without damage:
RJ Jack: 66V DC or 55V AC
F-Connector: 50V DC or AC
•Battery Life: 9V alkaline battery typical
Standby: 4 years
Active: 425 hours
•Cable Types: Shielded or Unshielded; Cat7, Cat6x, Cat5e,
Cat5, Cat4, Cat3, Coax
•Maximum RJ Cable Length: 0 to 1,000 feet (305 meters)
•Minimum Cable Length for Split Pair Detection:
1.5 feet (0.5 meters)
•Maximum Coax Cable Length:
BATTERY REPLACEMENT
1) Remove single screw in the middle of the back
of the VDV MapMaster™ with a #1 Phillips head
screwdriver. Remove the battery door.
2) Remove the old battery and disconnect
battery cable.
3) Replace with an ANSI 1604A, 9 volt alkaline
battery (Energizer 522, Duracell Mn1604). Reattach
cable and insert into battery compartment.
4) Replace battery door and screw.
DO NOT OVERTIGHTEN!
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
•TheVDVMapMaster™isdesignedforuseonunenergizedcabling
systems. Connecting the VDV MapMaster to live AC power may
damage it and pose a safety hazard for the user.
•PoorlyterminatedRJplugshavethepotentialtodamagethejacksonthe
VDV MapMaster™. Visually inspect an RJ plug before inserting it into the
tester. The contacts should always be recessed into the plastic housing
of the plug. Plugging 6-position plugs into the 8-position jack on the
tester has the potential to damage the outermost contacts of the jack
unless the plug is specifically designed for that purpose.
1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Platinum Tools VDV MapMaster and is the answer not in the manual?

Platinum Tools VDV MapMaster Specifications

General IconGeneral
BrandPlatinum Tools
ModelVDV MapMaster
CategoryTest Equipment
LanguageEnglish