EasyManuals Logo

PLS Access EA Series User Manual

PLS Access EA Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
7
Installation
1. Check Hand Pump
DOWN
Check Pump
2. Load Test
UP
3. Stowing/Overload Test
Turn clockwise to increase
Turn anticlockwise to decrease
STOW
UP
SWL
25 kg
Turn clockwise to increase
Turn anticlockwise to decrease
UP
4. Creep Test
15 min
Creep less than 10 mm
Creep over 10 mm
10 mm MAX
5. Installation Weight Test
SWL
+125%
SWL
Pressure Relief Vavle
Pressure Switch
7.8 Weight Test Access™ EA & Access™ EAB
Full Cycle Load Test
7
Installation
7.7 Burst Valve Test Procedure Access™ EA & Access EAB
Set Burst Valves To 0.5mm With a Set Of Feeler Gauges
( ensure lift is lowered To ground & Fully depressurised )
Connect Crash Test Kit To Lift
Re-pressurise lift & Operate to Full Stow Height
(Create Safe Area For Testing & Check The Area Is
Clear)
Keeping a Safe
Distance From The Lift.
Open the Crash Test
Valve
Close Crash Valve & Deploy The Lift
Add 25Kg To End Of The Platform
Keeping a Safe
Distance From Lift.
Open the The Crash
Test Valve
Lift Should Stop Or Lower At A
Controlled Speed (adjust Gap To
Suit)
Lift Should Stop Or Lower At A
Controlled Speed (adjust Gap To
Suit)
ADJUST VALVE GAP
To 0,5MM
25kg