Volume logger MacR6
Installation Manual
6
6. Configuration with the SMS message
Device have option to configure its settings with SMS message. In order to do this, number of used in
MacR6 SIM card is required.
Structure of SMS message is following:
K; authorization password; parameter_1=new_value; parameter_2= new_value;.. ;parameter_n
= new_value;
K Note that this is configuration message
Authorization password data which authorize the message (for modification), by default value 4096
parametr_1, parametr_2, parametr_n string of letters (abbreviation) which is assigned to every modi-
fiable parameter, detailed information are available in table with most common configured parameters
new_value new value of modified parameter. As a decimal separator use period (recommended) or
comma
Sending SMS message without configured parameters (SMS in form: K; 4096;”), may be used
for verification of device set up
List of most common configured parameters:
Parameter
abr
Additional info
Volume counter
v=
Pulse rate
w=
Available options: [1],[ 10],[ 100],[ 1000]
schedule
h=
configure frequency of data report: everyday [1], once a week[2], once a
month [3]
Report hour
g=
Report day
d=
APN name
apn=
Data server address
asd=
Consist of address separated with colon from number of port. i.e.:
www.ewebtel.com:80
NTP server address
ntp=