GOLD 1-3 SK-GB -708
Right to make modifications without prior notice
:
:: :
Commissioning, operation,
and maintenance: GOLD 1-3
1. INTRODUCTION ............................................................ 1
2. ELECTRICAL CONNECTION ........................................ 4
3. CONNECTION OF EXTERNAL FUNCTIONS ............... 5
4. WIRING DIAGRAM POWER CARD .............................. 6
5. WIRING DIAGRAM CONTROL CARD .......................... 7
6. STARTING-UP ............................................................... 8
7. ADJUSTMENTS ............................................................. 9
8. FUNCTIONS ................................................................. 13
9. ADJUSTMENT PROTOCOLE...................................... 18
10. ALARM ......................................................................... 19
11. MAINTENANCE ............................................................ 21
TELEPHONE NUMBERS PM-LUFT ............................ 22
INDEX
1. INTRODUCTION
1.1 GENERAL
GOLD is a complete air handling unit, with built-in control
system, developed and manufactured by PM-LUFT AB.
The unit contains supply and exhaust air fans, rotary heat
exchanger Turbo, supply and exhaust air filters F85/EU7
and control system.
These instructions are for the commissioning, operation,
and maintenance of the unit. It is important that they are
read by all personnel involved before the unit is put into
service. Please see separate instructions for installation
WARNING!
Inspection hatches located on the pressure side behind
the fan must not be opened while the fan is operating. The
hatch can open suddenly and cause personal injury.
Question and Answer IconNeed help?

Do you have a question about the PM-LUFT GOLD 1 and is the answer not in the manual?

PM-LUFT GOLD 1 Specifications

General IconGeneral
BrandPM-LUFT
ModelGOLD 1
CategoryAir Handlers
LanguageEnglish

Summary

2. Electrical Connection

2.1 Power and Safety

Details on power connection for different unit sizes, including safety features like the lockable isolator switch.

2.5 Reheater

Technical details for electrical heater and watercoil connections, including power supply and control signals.

3. Connection of External Functions

3.1 General and Basic Controls

Connecting external functions like stop, fire/smoke, and basic speed/set value controls.

3.8 Cooling Unit Control

ON/OFF and stepless control options for external cooling units.

7. Adjustments

7.2 Switching Clock & Programming

Programming desired times for high speed operation and understanding the programming menu.

7.4 Temperature Control

Adjusting temperature regulation (ERS) and other temperature control modes.

7.5 Flow and Damper Settings

Setting supply/exhaust air flows and adjusting the throttle damper for air balance.

8. Functions

8.2 Summer Night Cooling

Details on the summer night cooling function, its conditions for starting and stopping, and display text.

8.3 Outdoor Air Temperature Compensation

How outdoor air temperature displaces set values for supply/exhaust air, with compensation curves.

10. Alarm