TMS Quick Reference.doc Page 1 of 2 July 1, 2009
TMS Quick Reference Guide
Alarm LEDs*
Display Mode LEDs
LEAK In-Tank / Sensor GAL – Gross Volume (Gallons)
Net Volume (with ºF LED on)
SP1 Above 95% (High High) %GAL – Percent of Capacity
SP2 Above 90% (High) ULL – Ullage Vol (Gallons, Default 90%)
SP3 Below 20% (Low) IN – Product Level (Inches)
Water Level (with “u” symbol, inches)
WATER Above 2” ºF – Product Temperature (ºF)
Front Panel Buttons
PAPER FEED PRINT MODE TANK SELECT TEST
Press to advance Press for Current Press to display tank name. Press to select tank Press to test
paper Inventory / Sensor Press and hold until beep Press and hold until display and
Status report to select display mode beep for autoscan horn
STEP
GROUP SELECT EDIT
Current Inventory / Sensor Status Report:
Press PRINT button.
* If an alarm LED is blinking, an active tank alarm is present on a tank(s) not currently being displayed. When
an alarm LED is on continuously, it applies to the currently displayed tank. Note that this alarm may apply to
more than one tank, which can be determined by viewing each tank with the TANK SELECT button.
Site Name
Tech Support Phone
Site Location
Emergency Phone
Audible Alarm
Acknowledgment
To silence an alarm,
press any of the right
three buttons. The visual
indicator will remain
active as long as the
alarm condition persists.
A theft alarm can only
be silenced by pressing
the ACKNOWLEDGE
pushbutton located on
the inside of the front
door.
Visual Alarm
Acknowledgment
The only visual alarms
that can be cancelled
are failed in-tank leak
test and no monthly in-
tank leak test. These
visual alarms are
deactivated by pressing
the ACKNOWLEDGE
pushbutton located on
the inside of the front
door. All other visual
alarms are persistent
until remedied.
Question and Answer IconNeed help?

Do you have a question about the Pneumercator TMS 3000 and is the answer not in the manual?

Pneumercator TMS 3000 Specifications

General IconGeneral
BrandPneumercator
ModelTMS 3000
CategorySecurity System
LanguageEnglish

Summary

System Indicators

Alarm LEDs

Describes various alarm conditions indicated by LEDs: LEAK, SP1 (High High), SP2 (High), SP3 (Low), and WATER.

Display Mode LEDs

Explains different display modes shown on the system: GAL, %GAL, ULL, IN, and °F.

Alarm Acknowledgment Procedures

Audible Alarm Acknowledgment

How to silence audible alarms using front panel buttons; visual indicators remain active until condition is resolved.

Visual Alarm Acknowledgment

Details on cancelling specific visual alarms (failed leak tests) via the ACKNOWLEDGE pushbutton.

Front Panel Controls

Paper Feed and Print Buttons

Functionality of PAPER FEED (advance paper) and PRINT (status report) buttons.

Mode and Tank Select Buttons

Using MODE (display tank name) and TANK SELECT (select tank, autoscan) buttons.

Test Button

Purpose of the TEST button: to test display and horn.

Print Log Procedure

Entering Access Mode

Steps to enter access mode by holding TEST and MODE buttons until 'Log' is displayed.

Printing Logs

Procedure for selecting and printing specific logs such as Events, Alarms, or Sales.

Returning to Normal Mode

Methods to return to normal tank gauging display mode after operations.