kfranklinAug 2, 2025
What to do if the POBEL DESA 0041 overheats and activates the safety mechanism?
- RrussellralphAug 2, 2025
If the POBEL Water System overheats and the safety mechanism is activated, press the RESET button.
What to do if the POBEL DESA 0041 overheats and activates the safety mechanism?
If the POBEL Water System overheats and the safety mechanism is activated, press the RESET button.
What to do if the POBEL DESA 0041 has adequate water supply but distillation does not happen?
If the POBEL Water System has adequate water supply but distillation does not occur: 1. Check level switch N. If the circuit closes upwards and activates contactor C1, replace the switch if necessary. 2. If there is current supply to the input of contactor C1 but it does not work, replace it. 3. If there is current supply to the resistance (R, R1, R2, R3) but it does not heat, replace the resistance.
Brand | POBEL |
---|---|
Model | DESA 0041 |
Category | Water System |
Language | English |
Identifies key components and controls on the front of the water distiller unit.