27
POWER button
Press to turn the dehumidifier on and off.
COMFORT button
Press to starts/stops the comfort dehumidifying operation.
Note: On this operation, the unit can not be set humidity level. For some
models, under comfort dehumidifying operation, press Up/Down button will
cancel this feature.
Display
Shows the set % humidity level from 35% to 85% or auto start/stop time
(0~24) while setting, then shows the actual (±5% accuracy) room % humidity
level in a range of 30% RH (Relative Humidity) to 90 % RH (Relative
Humidity).
Error Codes and Protection Code:
AS-Humidity sensor error--Unplug the unit and plug it back in. If error
repeats, call for service.
ES-Tube Temperature sensor of the evaporator error--. Unplug the unit and
plug it back in. If error repeats, call for service.
P2-Bucket is full or bucket is not in right position-- Empty the bucket and
replace it in the right position. (only available for the unit with no pump
feature.)
Eb-Bucket is removed or not in right position—Replace the bucket in the right
position. (only available for the appliance with pump feature.)
Note: When one of the above malfunctions occurs, turn off the appliance,
and check for any obstructions. Restart the appliance, if the malfunction
is still present, turn off the appliance and unplug the mains power cable.
Contact the manufacturer or its service agents or a similar qualified service
person for service.
Other features
Bucket Full Light
Glows when the bucket is ready to be emptied.
Auto Defrost
When forst builds up on the evaporator coils, the compressor will cycle off
and the fan will continue to run until the frost disappears.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or when the bucket is