2928
removed or not replaced in the proper position.
For some models, the fan motor will continue to run for 30 seconds.
Wait 3 minutes before resuming operation After the unit has stopped, it can
not be restart operation in the first 3 minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
Check filter feature
The system starts to count the time once the fan motor operates. The check
filter feature can be only activated when the accumulated operation time
achieves 250 hours or more. The Reset light (Clean filter indicator light)
flashes at one time per second, after finishing clean the air filter, press the
Filter button and the Reset light (Clean filter indicator light) goes off.
Auto-Restart
If the appliance breaks off unexpectedly due to the power cut, it will restart
with the previous function setting automatically when the power resumes.
Setting the Timer
z
When the appliance is on, first press the Timer button, the Timer Off
indicator light illuminates. It indicates the Auto Stop program is initiated.
Press it again the Timer On indicator light illuminates. It indicates the Auto
Start is initiated.
z
When the appliance is off, first press the Timer button, the Timer On
indicator light illuminates. It indicates the Auto Start program is initiated.
Press it again the Timer Off indicator light illuminates. It indicates the Auto
Stop is initiated.
z
Press or hold the UP or DOWN button to change the Auto time by 0.5 hour
increments, up to 10 hours, then at 1 hour increments up to 24 hours. The
control will count down the time remaining until start.
z
The selected time will register in 5 seconds and the system will
automatically revert back to display the previous humidity setting.
z
When the Auto Start & Auto Stop times are set, within the same program
sequence, Timer On Off indicator lights illuminate identifying both On and
Off times are now programmed.
z
Turning the appliance On or Off at any time or adjusting the timer setting
to 0.0 will cancel the Auto Start/ Stop function.
z
When LED display window displays the code of P2, the Auto Start/Stop
function will also be cancelled.