31
will stop the water flowing. Make sure the water hose is lower than the
drain hose outlet of the unit.
z
Select the desired humidity setting and fan speed on the unit for
continuous draining to start.
Note: When the continuous draining feature is not being used, remove the
drain hose from the outlet, and dry the water in the continuous drain hose
outlet.
3. Pump draining (on some models)
z
Water can be automatically emptied into a floor drain or a suitable
drainage facility by attaching the pump drain outlet with a pump drain
hose (
Φ
od=1/4", supplied).
z
Remove the continuous drain hose from the appliance and install the
plastic cover to the continuous drain hose outlet of the appliance by
clockwise rotation.
z
Reset the pump drain hose into the pump drain hose outlet for depth of
15mm at least, then lead the water hose to the floor drain or a suitable
drainage facility.
Reinstall the
plastic cover
Pump drain hose
Pump drain hose outlet
z
Press the pump pad of the unit to activated the pump operation. When
the bucket is full the pump starts to work.
Note: The pump may cause big noise when it starts to work for 3-5 minutes.
It is a normal phenomenon.
z
Make sure the hose is secure so there are no leaks.
z
Direct the hose toward the drain, making sure that there are no kinks that
will stop the water flowing.
z
Place the end of the hose into the drain and make sure the end of the hose