K
Katrina RoachSep 23, 2025
How to reset RTC on Polar Electro Chiller?
- BbrownpatrickSep 23, 2025
Re-set date and time. For details, see “Section 12.1: Service” in the controller manual supplied with the appliance
How to reset RTC on Polar Electro Chiller?
Re-set date and time. For details, see “Section 12.1: Service” in the controller manual supplied with the appliance
Why is my Polar Electro Chiller leaking water?
If your Polar Electro Chiller is leaking water, consider these possible causes and solutions: * The appliance may not be properly leveled. Adjust the screw feet to level it. * The drain might be blocked. Clear the discharge outlet. * Movement of water to the drain might be obstructed. Clear the floor of the appliance, if applicable. If water is leaking from the back of the container, the water container could be damaged, in that case it is better to call a POLAR agent.
How to fix a loud Polar Electro UA014 Chiller?
If your Polar Electro Chiller is making unusual loud noises, there are a couple of things to check: * The appliance may not be installed on a level or stable surface. Check the installation position and adjust if needed. * There might be loose nuts or screws. Check all nuts and screws and tighten them.
What does it mean if my Polar Electro UA014 Chiller is beeping and showing a message?
If your Polar Electro Chiller is beeping and displaying a message on the control panel, this indicates a problem with the unit, signaled by the control alarm. See table below.
Why does food from my Polar Electro UA014 Chiller have freezer burns?
If food from your Polar Electro Chiller has freezer burns after removal, the selected cycle may not be suitable for the food. Change the cycle from hard freeze to soft freeze.
What does EVAPORATOR PROBE mean on Polar Electro Chiller?
Same as for the cabinet probe error but with reference to the evaporator probe. Check that the probe is undamaged. Check the device-probe connection. Check the cabinet temperature. If problem persists, Call POLAR agent or qualified technician.
What does NEEDLE PROBE SENSOR 1/2/3 mean on Polar Electro Chiller?
Same as for the cabinet probe error but with reference to needle probe 1/2/3. Check that the probe is undamaged. Check the device-probe connection. Check the cabinet temperature. If problem persists, Call POLAR agent or qualified technician.
What does CONDENSER PROBE mean on Polar Electro Chiller?
Same as for the cabinet probe error but with reference to the condenser probe. Check that the probe is undamaged. Check the device-probe connection. Check the cabinet temperature. If problem persists, Call POLAR agent or qualified technician.
What does DOOR OPEN mean on Polar Electro Chiller?
Check the door status.
What to do if my Polar Electro Chiller is beeping and a message appears on the control panel?
If your Polar Electro Chiller is beeping and displaying a message on the control panel, it indicates a problem with the unit. Consult the table below to identify the issue.
| Brand | Polar Electro |
|---|---|