MAINTENANCE AND LUBRICATION
Minor Maintenance
NOTE: During charging, if the electrolyte temperature rises above
115°F(45°C) reduce the charging rate to lower the temperature.
Increase the charging time.
3. After the battery is charged, check the fluid level. If it has dropped
add distilled water to bring the electrolyte up to the proper level.
4. Check the results of charging. The specific gravity of each cell
must be 1.26 at room temperature. The voltage should be 14.5 -
15.5 V during charging; 12.2 -12.8 V after charging.
Battery Installation
Always connect battery cables in the order specified. Red (positive)
cable first, black (negative) cable last.
1. Install the battery in its
holder.
2. Install the battery vent
tube. It must be free from
obstructions and securely
installed. If not, battery
gases could accumulate
and cause an explosion.
Avoid s kin contact with
electrolyte, severe burns
could result.
3. First connect and tighten
the red (positive) cable.
4. Second connect and tighten the black (negative) cable.
5. Apply dielectric grease PN 2871066 to each cable.
6. Reinstall the battery cover and electrical box over the battery and
reconnect straps.
Top View of Battery
Vent
T ube
Red (+)
Black (-)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris Virage 2002 and is the answer not in the manual?

Polaris Virage 2002 Specifications

General IconGeneral
ManufacturerPolaris
ModelVirage
Year2002
CategoryBoat
TypePersonal Watercraft
Seating Capacity3 persons
Fuel SystemCarbureted
Engine Type2-stroke

Related product manuals