ELECTRICAL
Starter
Motor
Starter
Assembly
Cont.
6.
Be
sure
wire
insulation
is
in
place
around
positive
brush
wire
and
pushed
completely
into
slot
on
phenolic
plate.
7.
Using
a
non-petroleum
grease,
lubricate
brush
end
bushing
and
install
shims.
8.
Align
brush
plate
and
install
cover
and
screws.
9.
Reinstall
bolts
and
tighten
evenly
and
securely.
10.
Lightly
grease
pinion
shaft
and
install
pinion,
spring
stopper,
and snap
ring.
Starter
Solenoid
Bench
Test
To
measure
the
resistance
of
the
pull-in
coil,
connect
one
meter
lead
to
the
Yellow/Red
wire
and
the
other
to
ground.
The
resistance
should
be
2.8-3.6
ohms.
Refer
to
Electric
Starter
System
Testing
in
this
section
to
further
test
the
solenoid.
Polaris
Sales
Inc.
7.17
3/00