F2-V2-M4 Owners Manual 10/20/2017
Air System
The F2 system is designed to operate with input pressure between 45 and 145 PSI using either HPA (High Pressure Air) or
Nitrogen. A suitable air system will be required. This includes a compressed air tank, regulator(s), remote line and fittings.
DO NOT APPLY PRESSURE GREATER THAN 145PSI.
CO2 IS NOT RECOMMENDED.
Installation
The best results are usually obtained when the replica body and gearbox are the same brand and model.
Preparation
Before installing the F2 the unused components must be removed from the gearbox and the remaining grease should be
cleaned out. In most cases, the only remaining parts will be the trigger, safety mechanism, selector plate, spring guide (if
applicable) and cutoff lever (if applicable). Keep the screw mounting screw from the AEG trigger contacts. This will be used
to mount the F2 switchboard in the same location.
Switchboard and Cylinder
Once the gearbox has been prepared, install the switchboard into the gearbox shell and secure it using the screw saved
from disassembly.
Place F2 in the cylinder window of the gearbox and plug the solenoid wires into the switchboard ports (shown below).
Question and Answer IconNeed help?

Do you have a question about the PolarStar F2 and is the answer not in the manual?

PolarStar F2 Specifications

General IconGeneral
ModelF2
FCU Battery ConnectorJST
TypeHPA (High Pressure Air)
ManufacturerPolarStar
Battery7.4V LiPo

Summary

Air System

Air System Operation and Safety

Details operating pressure limits (45-145 PSI) and advises against CO2.

Installation

Preparation for Installation

Instructions for cleaning the gearbox and removing excess components.

Switchboard and Cylinder Installation

Mount the switchboard and connect solenoid wires to the F2 unit.

Assembly and Adjustment

Gearbox Reassembly and Integration

Reassemble gearbox, route wiring, and install into the replica body.

Nozzle Alignment Check

Verify nozzle centering with hopup and barrel; shimming may be needed.

Velocity and Dwell Adjustment

Guide to setting velocity via air pressure and dwell for optimal performance.

Maintenance

Disassembly and Maintenance Procedures

Overview of how to disassemble the F2 unit for cleaning and maintenance.