Do you have a question about the poolstar POOLEX JETLINE PREMIUM FI 75 and is the answer not in the manual?
Describes the correct procedure for performing work on the unit to minimize risks.
Checking for flammable gas presence using a suitable detector before and during work.
Ensuring appropriate fire extinguishing equipment is available for hot work.
Strict prohibition of heat, flame, or spark sources near refrigerant components.
Specifications for replacement parts and controls for flammable refrigerants.
Initial safety checks and component inspections for electrical appliances.
Installation must be by a qualified professional to prevent injury or damage.
Disconnect power for defects/malfunctions; repairs by authorized services only.
Essential instructions for safe operation and maintenance of the equipment.
Rules and guidelines for choosing the heat pump's installation site.
Detailed instructions for making the hydraulic connection using a bypass kit.
Regulations and cable requirements for electrical connection.
Step-by-step guide for connecting power supply and circulating pump.
How fault codes are displayed and where to find troubleshooting information.
Table of common anomalies, possible causes, and recommended actions.
| Model | POOLEX JETLINE PREMIUM FI 75 |
|---|---|
| Type | Heat Pump |
| Power Supply | 400V, 3-phase, 50Hz |
| Water Connection | 50 mm |
| Refrigerant | R410A |