7 - ENG
HAZARD
RISK FROM NOISE
WHAT CAN HAPPEN HOW TO PREVENT IT
• Undersomeconditions
and duration of use, noise
from this product may con-
tribute to hearing loss.
• Alwayswearproperhearing
protection during use.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
SPECIFICATIONS
Model No. C2004
Bore 1.875" (47.6 mm)
Stroke 1.250" (31.8 mm)
Voltage/Hz-Single Phase 120/60
Minimum Branch Circuit Requirement 15 amps
Branch Circuit Fuse Type Time Delay
Air Tank Capacity 4 Gallons (15.1 liters)
Approximate Cut-in Pressure 135 psig
Approximate Cut-out Pressure 165 psig
SCFM @ 90 psig 2.6 *
Regulated Pressure Rating (Approximate) 3–150 psi
Quick Connect Type 1/4" (6.4 mm) Industrial
Noise Level 75.5 dBA +
* Tested per ISO 1217
+Tested per ISO 3744:1995
Refer to Glossary for abbreviations.
DECLARED NOISE EMISSION VALUES PER ISO 3744
Noise Emission Values
Sound Pressure Level: LpA = 75.5 dBA re 20μPA
Uncertainty in the Sound
PressureLevel: KpA=3.0dBAre20μPA
Sound Power Level: LwA = 88.0 dBA re 1 pw
Uncertainty in the Sound
PowerLevel: KwA=3.0dBAre1pw
The sum of the emission value and the uncertainty is the limit below which there is
a 95% confidence the value of a single tool will lie below when the tool is new.