Single-Stage Oilfree
Compressor
Instruction
manual
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No._______________________________________
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
Part No. D26348-023-0
®
ESPAÑOL: PÁGINA 21
FRANÇAISE : PAGE 41
To learn more about Porter-Cable
visit our website at:
http://www.porter-cable.com
MODEL
CPF6020
Copyright © 2002 Porter-Cable Corporation
PROFESSIONAL POWER TOOLS

Questions and Answers

  • M
    mkingAug 20, 2025
    What to do if my Porter-Cable CPF6020 is not supplying enough air?
    • J
      johnsondavidAug 20, 2025
      If your Porter-Cable Air Compressor isn't providing enough air, it might be due to prolonged excessive use, meaning you should decrease air usage. The compressor might not be large enough for your air needs, so check the accessory's air requirements and consider a larger compressor if needed. A restricted air intake filter can also cause this, so clean or replace it. Check for holes in the hose and replace if necessary. A restricted check valve can also be the cause, so remove and clean, or replace it. Finally, tighten any loose fittings to address potential air leaks.
  • J
    Jonathan JohnstonAug 22, 2025
    How to fix air leaks at the check valve of my Porter-Cable Air Compressor?
    • L
      Luke BakerAug 22, 2025
      If you notice air leaks at or inside the check valve of your Porter-Cable Air Compressor, it's likely due to a malfunctioning or dirty check valve. A malfunctioning check valve often causes a constant air leak at the pressure release valve when the tank is pressurized and the compressor is off. To fix this, drain the tank, then remove and clean or replace the check valve. Be careful not to overtighten it.
  • E
    Elizabeth ParkAug 25, 2025
    How to stop air leaks at fittings on my Porter-Cable CPF6020?
    • B
      Brianna BakerAug 26, 2025
      If your Porter-Cable Air Compressor has air leaks at the fittings, it's likely because the tube fittings aren't tight enough. Tighten the fittings where you hear air escaping. You can also check the fittings with a soapy water solution to find the leaks. Be careful not to overtighten the fittings.
  • C
    Christopher MortonAug 27, 2025
    How to fix air leaks between the head and valve plate on my Porter-Cable CPF6020?
    • A
      Allen HayesAug 28, 2025
      If there are air leaks between the head and valve plate on your Porter-Cable Air Compressor, it's likely due to a leaking o-ring. Try torquing the head screws to 8 ft. lbs. If the leak persists after tightening, you'll need to replace the o-ring.
  • K
    Kimberly DawsonAug 30, 2025
    Why does the safety valve keep popping off on my Porter-Cable CPF6020 Air Compressor?
    • E
      eric19Aug 30, 2025
      If the safety valve on your Porter-Cable Air Compressor is popping off due to excessive tank pressure, it could be that the pressure switch isn't shutting off the motor when the compressor reaches its cut-out pressure, or the pressure switch cut-out is set too high. Try moving the pressure switch lever to the OFF position. If the unit still doesn’t shut off, the electrical contacts may be welded together, requiring you to replace the pressure switch. Contact an authorized service center to check and replace the pressure switch.
  • A
    Andrew AdamsSep 2, 2025
    What to do if my Porter-Cable CPF6020 leaks air at the pressure switch release valve?
    • A
      Aaron BoydSep 2, 2025
      If your Porter-Cable Air Compressor is leaking air at the pressure switch release valve, it could be due to a malfunctioning pressure switch release valve or a malfunctioning check valve. You should remove and replace the release valve. If the check valve is the issue, it will cause a constant air leak at the pressure release valve when the tank is pressurized and the compressor is off. In this case, drain the tank and then remove, clean, or replace the check valve. Be careful not to overtighten.
  • D
    Danielle RoseSep 4, 2025
    Why is my Porter-Cable CPF6020 leaking air from the safety valve?
    • S
      stephanietorresSep 4, 2025
      If your Porter-Cable Air Compressor has an air leak from the safety valve, there might be a defect in the safety valve itself. Try manually operating the safety valve by pulling on the ring. If the valve continues to leak after that, it should be replaced.
  • D
    David BurgessSep 6, 2025
    Why is my Porter-Cable CPF6020 Air Compressor making a knocking noise?
    • H
      Hayley WilliamsSep 7, 2025
      A knocking noise in your Porter-Cable Air Compressor is often caused by a malfunctioning check valve. Remove and clean, or replace the check valve to resolve this issue.
  • G
    Gabrielle StephensSep 9, 2025
    Why does the pressure drop on my Porter-Cable CPF6020 when using an accessory?
    • V
      Vincent LeblancSep 9, 2025
      It's normal for some pressure drop to occur on the regulated pressure gauge of your Porter-Cable Air Compressor when an accessory is in use. However, if the pressure drop is excessive, adjust the regulator following the instructions on page 7. Make sure to adjust the regulated pressure under flow conditions, meaning while the accessory is being used.
  • D
    Diane RamirezSep 12, 2025
    What causes continuous air leak from regulator knob on Porter-Cable Air Compressor?
    • J
      Jonathan EstesSep 12, 2025
      If the regulator knob on your Porter-Cable Air Compressor has a continuous air leak or the regulator won't shut off the air outlet, it could be due to the pressure release valve on the pressure switch not unloading head pressure or a damaged regulator. The solution is to replace the regulator.

Summary

Safety Guidelines and Definitions

Hazard Symbol Definitions

Explains hazard alert symbols like DANGER, WARNING, and CAUTION.

Important Safety Instructions

Key safety guidelines for operating the compressor and preventing hazards.

Hazards and Prevention

Risk of Explosion or Fire

Identifies fire/explosion risks and provides prevention measures.

Risk of Bursting

Details risks associated with the air tank and its components.

Risk from Flying Objects

Covers hazards from compressed air streams and projectiles.

Risk of Electrical Shock

Explains electrical hazards and necessary precautions.

Risk to Breathing

Addresses hazards from inhaling compressed air or sprayed materials.

Risk of Burns

Warns about touching hot compressor parts.

Risk from Moving Parts

Highlights dangers from moving components like belts and pulleys.

Risk of Falling

Covers potential falls of the portable compressor.

Risk of Property Damage When Transporting Compressor

Addresses risks like oil leaks during transport.

Risk of Unsafe Operation

Covers general unsafe practices leading to injury or death.

Glossary and Specifications

Glossary of Terms

Defines common terms used in the manual, like CFM, SCFM, PSIG.

Duty Cycle Explanation

Explains the recommended duty cycle for air compressors.

Compressor Specifications

Lists technical details of the CPF6020 model.

Assembly and Accessories

Assembly Tools Required

Lists the tools needed for assembling the compressor.

Unpacking Instructions

Steps for safely unpacking the compressor unit.

Component Assembly

Guides for assembling the handle, wheels, and rubber feet.

Installation and Setup

Unit Setup and Location

Guidelines for positioning the compressor in a suitable area.

Grounding Instructions

Details on proper electrical grounding for safety.

Extension Cord Guidelines

Recommendations for using extension cords with the compressor.

Voltage and Circuit Protection

Information on circuit requirements and protection.

Operation of the Air Compressor

Understanding Your Compressor

Introduces key controls and components of the compressor.

Component Descriptions

Explains the function of each control and part like switches, gauges, and valves.

Stopping the Compressor

Instructions on how to safely stop the compressor.

Before First Start-up Procedure

Essential break-in procedure before initial use.

Pre-Start Checks

Steps to perform before each startup.

Starting the Compressor

Detailed steps for starting and operating the compressor.

Maintenance and Service

Customer Maintenance Schedule

Outlines routine maintenance tasks and their frequency.

Checking the Safety Valve

Procedure for verifying the safety valve's functionality.

Draining the Air Tank

Steps for draining condensation from the air tank.

Air Filter Maintenance

Instructions for inspecting and replacing the air filter.

Pump Valve Service

Guidance on servicing air compressor pump intake and exhaust valves.

General Service and Adjustments

Information on repairs and adjustments performed by technicians.

Replacing the Regulator

Step-by-step guide to replacing the regulator assembly.

Storage

Pre-Storage Procedures

Steps to follow before storing the air compressor.

Limited Warranty Information

Warranty Coverage and Periods

Details warranty duration for different compressor parts.

Purchaser Responsibilities

Outlines what the user must do for warranty claims.

Warranty Exclusions

Lists conditions and usage not covered by the warranty.

Check Valve Maintenance

Replace or Clean Check Valve

Instructions for replacing or cleaning the check valve.

Porter-Cable CPF6020 Specifications

General IconGeneral
BrandPorter-Cable
ModelCPF6020
CategoryAir Compressor
LanguageEnglish