EasyManua.ls Logo

Powerfix Profi 270249 - Start-up and Settings; Setting Sensor Sensitivity

Powerfix Profi 270249
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 GB
Remove the screws
2
from the front of the motion detector (see Ill. B).
Insert the cable through the cable opening of the base plate
4
.
Screw the base plate
4
to the desired position.
Connect the cable to the screw terminal
3
of the motion detector as
depicted in Ill. C.
Attach the cover of the connection area back to the base plate
4
by
screwing the screws
2
.
Start-up
Turn the electricity back on. The device is now ready for use.
Setting the sensitivity of the sensor (Ill. D)
Only models Z31712C/D
Note: the sensor range is max. 12 m (depending on the surrounding
temperature).
Turn the control knob SENS
8
in the direction „-” in order to reduce
the sensor range
1
.
Turn the control knob SENS
8
in the direction „+” in order to
increase the sensor range
1
.