Owner’s Manual
Instructions for Installation/Set-up, Operation, Servicing, & Storage
Portable, Outdoor Use-Only, Gasoline Generator
166114 - 7250 Watt Continuous (9000 Watt Surge) Capacity
Can be used to power individual appliances plugged directly into the generator’s outlets, or as a
back-up connection to a building’s power supply (via a professionally installed UL-approved
transfer switch.
WARNING
READ and UNDERSTAND this manual completely before using the generator! Failure to properly set up,
operate, and maintain this generator could result in serious injury or death from carbon monoxide poisoning,
electric shock, fire/explosion, or burns. In particular, be aware of the following hazards:
CO Poisoning
Generators give off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it.
ONLY run generator OUTDOORS and AWAY from building air intakes. NEVER run generator inside any enclosed or
semi-enclosed spaces, including homes, basements, garages, sheds, boxes, RVs, boats or pick-up truck beds. These
spaces can trap poisonous gases, EVEN if you run a fan or open windows.
Install carbon monoxide alarms inside nearby structures/buildings (battery-operated, or plug-in with battery backup).
Electric shock / Electrocution
High voltage electricity from generator can kill. DO NOT operate in wet locations. Be sure generator is properly
grounded. Use only UL-listed, outdoor-rated grounded extension cords of proper size.
NEVER plug the generator directly into a wall outlet. ANY connection to a building’s electrical system MUST
ISOLATE THE GENERATOR FROM UTILITY POWER via a UL-approved transfer switch installed by a licensed
electrician. Otherwise, back feed from the generator into the power grid could kill utility workers.
Fire / Explosion
DO NOT overload generator (per rated capacity), and OPERATE ONLY in an area with adequate cooling ventilation so
engine does not overheat. Exhaust can be extremely hot. Keep muffler at least 7 feet from all combustible objects.
All fuels are flammable. Never fuel a running or hot engine. Never pump fuel directly into generator at gas station use
approved container to transfer fuel. Ensure there are no fuel leaks, and keep sources of sparks and flames away.
ALWAYS keep a fire extinguisher rated “ABC” nearby.
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS. See the “Power load Planning & Management” section
of this manual to determine your power load requirements and then compare to the generator’s rated capacity.
INSPECT COMPONENTS: Closely inspect to make sure no components are missing or damaged. See the “Unpacking
& Delivery Inspection” section for instructions on whom to contact to report missing or damaged parts.
ARRANGE FOR PROFESSIONAL INSTALLATION of a transfer switch if you will be connecting the generator to
your building’s electrical system. See the “Installation/Initial Set-Up” section for more information about this
requirement.
Any Questions, Comments, Problems, or Parts Orders
Call Powerhorse Product Support 1-866-443-2576
M166114H
ITEM NUMBER: 166114
SERIAL NUMBER:
_______________

Questions and Answers

Summary

Specifications

Machine Component Identification

Generator Installation & Setup

Planning the Power Load

Determine power needs for devices to avoid generator overload.

Portable vs. Building Back-Up Setup

Configure generator for direct appliance use or building backup power.

Selecting a Suitable Site

Choose a safe outdoor location with proper ventilation and clearance.

Grounding the Generator

Ensure proper grounding to prevent electrical shock hazards.

Generator Operation

General Safety Rules for Operation

Review essential safety practices before starting and during generator use.

Preparing for Operation

Steps to prepare the generator, including oil, fuel, and grounding.

Generator Maintenance & Repair

Generator Troubleshooting

Generator Safety Summary

Operation Safety

Covers pre-use, during-use, and post-use safety for operation.

Engine Operation & Maintenance

Engine Troubleshooting

Engine Specifications & Diagram

Powerhorse 166114 Specifications

General IconGeneral
Run Time at 50% Load10.5 hrs
Outlets2x 120V 20A (5-20R), 1x 120V 30A (L5-30R)
Weight108 lbs
Starting SystemRecoil
Noise Level68 dB
AC Output120V
Engine Type4-stroke, OHV
Fuel Tank Capacity4 gallons
DC Output12V