GENERATOR USE
Connections to a Building Electrical System
Connections for standby power to a building electrical system must be made by a qualified
electrician. The connection must isolate the generator power from utility power, and must
comply with all applicable laws and electrical codes. A transfer switch, which isolates generator
power from utility power, is available through authorized Honda generator dealers.
WARNING: Improper connections to a building electrical system can allow electrical current from
the generator to backfeed into the utility lines. Such backfeed may electrocute utility
company workers or others who contact the lines during a power outage, and the
generator may explode, burn, or cause fires when utility power is restored. Consult the
utility company or a qualified electrician.
Ground System
Generators have a system ground that connects generator frame components to the ground
terminals in the AC output receptacles. The system ground is not connected to the AC neutral
wire. If the generator is tested by a receptacle tester, it will show the same ground circuit
condition as for a home receptacle.
AC Applications
Before connecting an appliance or power cord to the generator:
Make sure that it is in good working order. Faulty appliances or power cords can create a
potential for electrical shock
If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off
immediately. Disconnect the appliance, and determine whether the problem is the appliance,
or if the rated load capacity of the generator has been exceeded.
Make sure that the electrical rating of the tool or appliance does not exceed that of the
generator. Never exceed the maximum power rating of the generator. Power levels between
rated and maximum may be used for no more than 30 minutes
NOTICE: Substantial overloading will open the circuit breaker. Exceeding the time limit for
maximum power operation or slightly overloading the generator may not switch the
circuit breaker or circuit protector OFF, but will shorten the service life of the
generator.
Limit operation requiring maximum power to 30 minutes. For continuous operation (longer than
30 minutes), do not exceed the rated power. The total power requirements (kW) of all
appliances connected must be considered. Appliance and power tool manufacturers usually list
rating information near the model number or serial number.
AC Operation
1. Start the engine.
2. Turn the voltage selector switch to either position.