➢ System Failure Diagnosing
Over Temperature
Protection
Check that the ambient temperature is not
higher than 45°C.
Battery pack Over Voltage
Protection
Disconnect the charger and restart the
unit.
Battery Damage Protection
Too low temperature when
discharging
The temperature of the battery is too low.
Increase battery temperature.
Battery Low Voltage
Protection
Please charge immediately. Fully charge
unit then restart.
Inverter Over Current
Protection
Check if the AC output overloaded or short-
circuited.
Inverter Over Load
Protection
Check if the AC output overload, please
refer to the technical spec for overload
ability.
Inverter Short - Circuit
Protection
Check if the AC output overloaded or short-
circuited.
Charging Over Voltage
Protection
Check if the input voltage exceeds the
maximum value.
Too low temperature when
charging
The temperature of the battery is too low.
Increase battery temperature to charge.
12V 10A Output Over
Current Protection
Check if the output overloaded or short-
circuited.
12V 10A Output Over Load
Protection
Check if the output overload.