9 CLEANING, MAINTENANCE, AND LUBRICATION
Before each use, inspect the general condition of the tool. Check for loose hardware,
misalignment or binding of moving parts, cracked or broken parts, damaged electrical
wiring, and any other condition that may affect its safe operation.
After Use, wipe external surfaces of the tool with clean cloth.
Periodically blow out the motor vent holes with compressed air to prevent the buildup of
dust and particles.
Periodically wipe the collet, collet cones, and cutting bits with a light oil to prevent rust.
Over time, if the performance of the tool diminishes, or it stops working completely, it may
be necessary to replace the carbon brushes by removing the brush holder cap. This
procedure must be completed by a qualified technician.
WARNING! If the supply cord of this power tool is damaged, it must be
replaced only by a qualified service technician.
10 TECHNICAL DETAILS
Model nr.
POWX0910
Voltage
230V
Mains frequency
50 Hz
Power
1200W
No load speed
11 000-30 000 min-1
Cutting depth
35 mm
Spindle diameter cutter
6/8 mm
11 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
88 dB(A)
Acoustic power level LwA
99 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
7.1 m/s²
K = 1,5 m/s²