15 P3500
Check the correct answer.
1 It is necessary to read the Operator’s Manual
prior to operating a Powers Fasteners low
velocity tool.
True False
2 When fastening into concrete, the base
material should be greater than the shank
penetration by at least:
1 time
2 times
3 times
3 When operating a powder actuated tool, your
hand should never be placed:
around the tool body
in front of the tool muzzle
over the tool handle
4 To determine the suitability of a base
material, use the fastener as a center punch.
If the fastener is blunted, do not fasten; the
material is too:
soft hard brittle
If the fastener penetrates easily, do not
fasten; the material is too:
soft hard brittle
If the material cracks or shatters, do not
fasten; the material is too:
soft hard brittle
5 Unsafe applications for powder actuated tools
may be caused by which of the following?
a soft base material
improper powder load
fastening too close to
an unsupported edge
a malfunctioning tool
fastening into a spalled area
fastening through a
pre-existing hole
all of the above
6 Which one of the following building materials
is not suitable as a receiving material (base
material) for powder actuated fasteners?
sheet rock
wood
fiberglass
sheet metal
all of the above
7 When considering the safety of a particular
application, the operator must think about:
the base material
the powder load power level
the operator’s safety
the safety of bystanders
and fellow workers
all of the above
8 The proper loading procedure is: insert fastener
first, powder load second. The fastener should
always be placed in the tool prior to the load.
True False
9 Which one of the following materials is
usually suitable for powder actuated
fastenings?
poured concrete
hollow tile
surface hardened steel
glazed brick
10 In concrete, a fastener should be
driven no closer to an unsupported
edge than:
1/2" 1-1/2" 3"
11 Fishhooking is a condition which
can occur when a powder actuated
fastener strikes a piece of hard aggregate or
very hard concrete, bends and comes out of the
work surface. A fishhook can cause a serious
injury or death.
True False
12 Placing a hand over the muzzle bushing of a
loaded tool can result in serious injury from
piston overdrive or an escaping fastener if the
tool is discharged accidentally.
True False
13 Piston overdrive is caused by overpowering of
the tool or by discharging the tool against a
soft surface.
True False
14 Malfunctioning tools cannot be used and
must be removed from service immediately.
True False
15 After conducting a Center Punch Test,
the best way to check the base material
is to set several fasteners using the least
powerful load.
True False
16 Safety goggles and hearing protection should
not be worn by the operator and any
necessary bystanders when using the tool.
True False
17 A powder actuated tool cannot be safely used
in an explosive or flammable atmosphere.
True False
18 List the proper powder load level number
(1-6) next to each
color listed.
Red ___ Brown ___
Green ___ Yellow ___
Gray ___ Purple ___
19 The weakest power level should
be used when making the first fastening.
True False
20 You can fasten into welded areas
of steel.
True False
P3500
The proper procedure if a powder load fails to
ignite is to hold the tool against the work
surface and wait 30 seconds, then proceed
exactly as directed in the Operator’s Manual.
True False
Powers Fasteners powder loads for the P3500
are .22 caliber, "A" tapered, neck down, rim
fire, short crimped cartridges. No other
powder load may be used in this tool.
True False
Operators should never compress the P3500
or any other powder actuated tool against
any part of their body.
True False
If a piston buffer for the P3500 becomes
deformed, simply remove it, and use the tool
without the buffer?
True False
OPERATOR’S NAME DATE
HOME ADDRESS
AGE DATE OF BIRTH
COMPANY NAME
COMPANY ADDRESS
COMPANY PHONE
SIGNATURE DATE
QUALIFIED TOOL OPERATOR EXAMINATION