TROUBLESHOOTING
will not
start.
Engine switch is set to "OFF".
Set engine switch to "ON".
Fuel valve is turned to "OFF".
Turn fuel valve to "ON" position.
Engine is filled with contaminated or old gas.
Change the gas in the tank.
Generator is not on level surface.
Move generator to a level.
Clean or replace air cleaner element.
runs but
there is no
output.
Circuit breaker button is off.
Wait for 2 minutes and move the circuit
breaker button to the "ON" position.
Bad connecting wires/cables.
If you are using an extension cord, try a
different one.
Bad electrical device connected to generator.
Try connecting a different device.
runs but
doesn’t
support all
electrical
devices
connected.
1. Turn off all electrical devices.
2. Unplug all electrical devices.
3. Turn off generator.
4. Wait several minutes.
5. Restart generator.
6. Try to connect fewer electrical loads
Short in one of the connected devices.
Try disconnecting any faulty or
short-circuited electrical loads.
Clean or replace air cleaner.