6. Settings Description
1.MAIN
This will display only when a battery is connected. It shows the current output
voltage to the battery.
2.FLOATING VOLTAGE
Pre-set at 13.8V. This is the maximum Voltage the battery will be charged to.
3.DISCHARGE RECONNECT
Pre-set at 12.6V. This is the Voltage that the
regulator will recommence output to the "output terminals" and the USB, in
situations where the "Discharge Stop" Voltage (pre-set at 10. 7v) has been
reached. This gives the battery some juice before power output
recommences.
4.DISCHARGE STOP
Pre-set at 10. 7V. This is the lowest Voltage the regulator will allow the battery
to reach, before disconnecting the output to the "output terminals" and the
USB. This protects the battery from over-discharging. Power will recommence
once the battery voltage reaches the "Discharge Reconnect" voltage (Pre-set
at 12.6v)
5.WORK MODE
Pre-set at 24H. This means the output to the "output terminal" and USB will
always be active (as long as there is sufficient power in the battery). Other
hour settings mean that the output to the "output terminals" and the USB will
continue for the set period of time after the last detection of light. For e.g. if
set at 1H, the regulator will continue output for an hour after the last detection
of light.
6.BATTERY TYPE
Set the type of battery you have. B01 is for sealed batteries. B02 is for colloid
batteries. B03 is for open batteries.
7.NOTICE
THE REGULATOR IS ONLY SUITABLE FOR LEAD ACID OPEN, AGM AND
GEL BATTERIES. IT IS NOT SUITABLE FOR NICKEL METAL HYDRIDE,
LITHIUM ION OR OTHER BATTERIES.
CHARGING WILL STOP IF THE BATTERY FALLS BELOW THE SELECTED
" DISCHARGE STOP" VOLTAGE. DEFAULT IS 10.7V.
6