5331V114-UK 5
Effectofsupplyvoltagevariation .................... < 0.005% of span / VDC
Vibration ...................................................................... IEC 60068-2-6 : 2007
2...25Hz .............................................................
±1.6 mm
25...100Hz .................................................. ±4 g
Max.wiresize ............................................................ 1 x 1.5 mm
2
stranded wire
Screw terminal torque ........................................... 0.4 Nm
Humidity ...................................................................... <95%RH(non-cond.)
Dimensions ................................................................. Ø 44 x 20.2 mm
Protectiondegree(enclosure/terminal) ....... IP68 / IP00
Weight .......................................................................... 50 g
Electrical specifications, input:
RTD and linear resistance input:
Max. offset ................................................................. 50% of selec. max. value
Cableresistanceperwire(max.) ....................... 5 Ω
Sensor current ........................................................... Nom. 0.2 mA
Effectofsensorcableresistance
(3-/4-wire) ................................................................ < 0.002 Ω/Ω
Sensor error detection ........................................... Yes
Basic values
Inputtype
Basic
accuracy
Temperature
coefficient
RTD ≤ ±0.2°C ≤ ±0.01°C/°C
Lin.R ≤ ±0.1 Ω ≤ ±10 mΩ / °C
Volt ≤ ±10 µV ≤ ±1 µV / °C
TCtype:
E,J,K,L,N,T,U
≤ ±1°C
≤ ±0.05°C / °C
TCtype:B,R,S,
W3,W5,LR
≤ ±2°C
≤ ±0.2°C / °C
EMCimmunityinfluence ................................................ < ±0.5% of span
ExtendedEMCimmunity:
NAMUR NE21,Acriterion,burst ............................... < ±1% of span
RTD
type
Min.
value
Max.
value
Min.
span Standard
Pt100
Ni100
Lin.R
-200°C
-60°C
0 Ω
+850°C
+250°C
5000 Ω
25°C
25°C
30 Ω
IEC 60751
DIN 43760
-----