955205_01 11/11 23
GPS Setup – Sidedress Bar
From the Home Screen, press Setup-Systems-
GPS-Sidedress Bar to enter the GPS
measurements for the bar. Frame Type is locked
on Single. Press Hitch Style to select Drawn,
2-Point Pivot, or 3-Point and press Enter. The
“A” measurement is measured from the pivot
point at the hitch to the center of the transport
wheels. The “B” measurement is measured
from the pivot point at the hitch to the point of
applicaon. The “C” measurement is the
eecve width of the bar, not the actual
measured bar width (lemost point of
applicaon to the rightmost point).
Setup and Operaon (Sidedress)
Motor Calibraon
Liquid motor calibraon is accessed from the
same motor setup screen. Press Motor
Calibraon at the top and then press the Gear
Rao buon. Enter the gear rao calculated
using the formula provided on this page and
then press Enter. If the Drive Motor is directly
coupled to the liquid pump, the Gear Rao will
be “1”. Press the Liquid Rao buon to open
the liquid motor calibraon screen. If you know
the number of ounces of product produced by
one pump revoluon, you may enter it here and
press Enter. You may also do a Liquid Run Cal to
get this number by pressing the buon at the
right side of the screen.
Motor Setup
Setup for liquid control motors can be accessed
from the standard RowFlow motor setup screen
for or by going to Setup-Systems-RF Liquid.
Select Drive Motor #2 and press Liquid. Select
the correct motor brand and then enter the
default rate at which you would like your
product to be applied and press Enter. Enter the
maximum speed (in RPM’s) for the liquid pump
as dened by the pump’s manufacturer
specicaons and then press Enter.