For technical questions, please call 1-888-866-5797.
ITEM 59186
SAFETY OPERATION MAINTENANCESETUP
Break-in Period:
a. Breaking-in the Engine will help to ensure proper equipment and Engine operation.
b. The break-in period will last about 30 hours of use.
DO NOT exceed 75% of the Generator’s running wattage during this period.
Change the engine oil after this period.
Under normal operating conditions subsequent maintenance follows
the schedule explained in the MAINTENANCE section.
Nominal 12VDC Output
1. Move the Economy (ESC) Switch
to the OFF position.
2. Only use the 12VDC receptacle to
charge a 12 volt lead-acid type battery
using an appropriate charge controller.
(Battery and controller not included.)
The 12VDC output is not regulated.
3. Do not connect any device to the 12VDC
terminal that draws more than 5 amps.
4. If the 12VDC circuit protection is tripped,
reduce the load, and press the
Reset Button next to the outlet.
OVERLOAD
GROUND
USB 5V DC
PARALLEL
OUTLETS
AC 120V
ESC THROTTLE
OUTPUT
CARBON
MONOXIDE
SHUTOFF
DC 5A
12V DC 5A
1.0A
2.1A
OFF
ON
RESET
START
OFF
RUN
12V DC 5A
Reset Button
12VDC
Receptacle
START
OFF
RUN
ON
OFF