10
PRED1200 SPECIFICATIONS
Net weight with filters: 70 lbs.
Power supply requirements: Minimum 120 VAC, 60 Hz, 15 A
Normal operating amps: 3.5 amps or less
Integrated circuit breaker: 12 amps
Motorized impeller:
400 watt motorized impeller with thermal overload protection,
set, 60 Hz, single phase.
Operating flow rate* (with clean filters): Variable, 300 – 900 CFM
67 dBA on high speed, reading taken at 5’.
Cabinet:
UL94HB flame retardant resin with EPA-Registered
Transportability:
2 each 8" rubber wheels in rear and 2 ea. 360° swivel casters in
Foam inlet plug:
Foam plug for sealing inlet to protect against spillage during
transit (P/N: PLUG10).
Pre-filter access:
Easy-operating hinged door is secured by rotating latch
to protect against filter by-pass.
First stage pre-filter: 1" deep coarse particulate pre-filter (P/N: F621).
Second stage pre-filter: 2" deep pleated particulate pre-filter (P/N: H502).
Optional third stage pre-filter: 2" deep high capacity carbon filter for odors (P/N: VL1002).
HEPA filter:
Tested and certified to an efficiency of 99.97% or higher against
0.3 micron size particles (P/N: H610C-99).
U.S. Design Patent No. D572,356
Note:
Specifications subject to change without notice.
*Airflow rating estimates are based on factory testing at 120 VAC, 60 Hz with an air straightener and a traverse
of readings taken with a computing vane-anemometer. Actual results may vary for various reasons, including
motor and blower and HEPA filter tolerances. Factors such as filter loading, reduced voltage to the motor, and
inlet and outlet ducting will reduce airflow. Use the ratings as a general guideline only.