The “TEST” button lets you check if the alarm system is working properly. During a test, you should see the red indicator
light up and hear the alarm.
In the event of a power failure, the alarm system continues to function on an emergency 9 V alkaline battery (not supplied).
Using a rechargeable battery is not recommended.
NOTE: Replace the emergency battery every 12 months, each time the alarm is activated, or whenever there is a power
failure. If the battery is weak, the system will beep once every minute. Replace the battery immediately when this occurs.
To replace the 9 V battery:
Disconnect the alarm box and remove it from the wall (the battery must be inserted on the side of the box).
Open the cover of the 9 V battery compartment and replace the battery with a 9 V alkaline battery.
Close the cover, reinstall the box on the wall, and reconnect it.
If the alarm is activated, press the “RESET/TEST” button to initialize it.
4.2 ELECTRICAL CONNECTIONS
All electrical connections must be done by a certified electrician. Using seal
connectors is mandatory. Premier Tech recommends installing the power
box on top of the pumping stations insulating board to avoid any issues with
humidity.
Use two separate circuit-breakers, one to operate the pump and the other
to connect the alarm box. Do not connect anything else to these circuit-breakers
(for example, a household appliance). They must be used exclusively for the
pump and the alarm box. In the case of commercial, community, institutional,
or municipal application, refer to your Premier Tech project manager.
5. WHAT TO DO IN CASE OF...
5.1 AN ACTIVATED ALARM
If an alarm is activated, unrelated to a power failure, contact Premier Tech so the problem can be identified and
corrected.
5.2 A PROLONGED POWER FAILURE
If a winter power failure is prolonged or if you are planning to shut down your system, protect the components
of your septic system against freezing.
If one of these situations occurs, or If you have any questions about restarting your system, contact Premier Tech.
5.3 FLOODING
Certain sites are prone to flooding or to rises in groundwater levels. This can lead to a malfunction in your septic
system or alter the performance of your Ecoflo compact biofilter. If this happens, contact Premier Tech.