Installation guide and Owner’s manual Page 1/10 20201029
Pumping stations PSA-240/H Item # 183036
Installation guide and Owner’s manual
Pumping stations PSA-240/H
This guide provides information regarding the installation, operation, maintenance and warranty of the PSA-240 and PSA-240H
Pumping Stations from Premier Tech. For additional information, contact our customer service at 1-800-632-6356
.
1. Technical data
PSA-240: The effective volume of the pumping station’s reservoir is of 150 L (40 US gallons, 33 Imperial gallons). The pumping station
can therefore be used for a treatment system with up to three Ecoflo
®
biofilters or with any other type treatment system that does not
require a dose volume greater than 150 L.
PSA-240H: The effective volume of the pumping station’s reservoir is of 255 L (67 US gallons, 56 Imperial gallons). This pumping
station is normally used to feed low pressure distribution systems for sand filters and seepage beds when a dosing volume between
150 and 255 L is required.
Models PSA-240 PSA-240H
Material (reservoir and lid)
Polyethylene
Polyethylene
Pump
120 V (197073)
120 V (314982)
Float
On/Off pump switch and alarm switch
Double On/Off pump switch and alarm switch
Inlet height
635 mm (25")
1 060 mm (41¾")
Water inlet and aeration duct
Adapted for all types of pipe Ø 100 mm (4") nominal
Adapted for all types of pipe Ø 100 mm (4")
nominal
Outlet height
1 015 mm (40")
1 015 mm (40")
Outlet
Adapted for a flexible pipe Ø 38 mm (1.5") nominal
Adapted for a flexible pipe Ø 50 mm (2") nominal
Total volume (at water inlet level)
240 L
400 L
Effective dosing volume
150 L
255 L
Weight
50 kg (110 lb)
56 kg (123 lb)
Adaptor
Biofilter inlet included
Certification
The pump, the float and the alarm system are all CSA certified (Canadian Standards Association)
* Depends on the treatment system with which it is paired. The pumping station operates according to the principle of connecting vessels.