CONVERTING RANGE FROM NATURAL GAS
TO PROPANE GAS
STEP 5 METHOD A or METHOD B Check Operation:
After the above conversion has been completed, check operation of cooktop and oven burner. Make air shutter
adjustments and set cook top pilots if necessary (See Page 28 for lighting and burner adjustments.).
24
STEP 4 METHOD A or B Convert Oven
Burner:
The oven burner orifice is located beneath
the inlet to the oven burner at the lower rear
portion of the broiler section. See Fig. 5
Using a 1/2” wrench turn the orifice hood
clockwise until it is snug.
Warning: Do not over-tighten the orifice
hood.
PIN
LP GAS
NATURAL GAS
ORIFICE HOOD
Fig. 5