5
or deformed. Therefore it will not operate properly and should be replaced. When replacing the sealing ring, replace the automatic
airvent.UseonlygenuinePresto
replacement parts.
Iftheautomaticairventiseverforcedoutofitscoveropeningduetoexcesspressurewhilecanning
orcooking,itisimportanttohavetheCannerproperlyinspectedbeforefurtheruse.Donotattemptto
replacetheautomaticairvent.SendtheentireCannertothePrestoFactoryServiceDepartment.
4. Besuretheventpipeisopenbeforeeachuse.Cleantheventpipewithasmallbrushorpipecleaner
(Fig.G).
5. WhenyourPressureCannerisnotinuse,invertthecoverontheCannerbodyandstoreinadryplace.
StoringtheCannerwiththecoverlockedonmaycauseunpleasantodorsandmaydeformthesealing
ring.
General Maintenance
1. UseonlygenuinePresto
replacement parts.
2. CAUTION: In time, the sealing ring may shrink and the automatic air vent may become hard and deformed or soft and sticky.
Exposuretohighheat,suchasawarmburneroroventop,willcausethesepartstodeteriorate.Whenthishappens,replacethesealing
ringandautomaticairvent.Beforeinsertinganewsealingring,cleanthesealingringgroovewithabrush.Toensuresafeoperation
ofyourPressureCanner,itisrecommendedtheautomaticairventbereplacedwheneverthesealingringisreplaced.Failuretofol-
low these instructions could result in bodily injury or property damage.
3. IftheCannerbodyorcoverhandlesbecomeloose,tightenwithascrewdriver.
4. IfleakageofmoistureorsteamdevelopswhileusingyourCanner,checkthefollowingpossiblecauses:
♦ Theformationofasmallamountofmoistureunderthepressureregulatorisnormalwhencanningrstbegins.Thiscondensation
isaresultofthetemperatureofthepressureregulatorbeinglowerthantherestoftheCanner.Ifexcesscondensationcontinues,
the vent pipe may be loose and should be tightened with an adjustable wrench.
♦ Leakagebetweenthecoverandbodyisusuallycausedbyshrinkageofthesealingringafterprolongeduse.Replacethesealing
ring and automatic air vent.
♦ A small amount of steam or moisture may be visible around the automatic air vent as canning begins. This will stop when the
automatic air vent seals. If leakage continues, clean or replace the automatic air vent.
DonotoperateyourPressureCannerwithcontinualleakage.Iftheabovestepsdonotcorrecttheproblem,returntheentireunitto
thePrestoFactoryServiceDepartment.
5. Thedialgaugeisadelicateinstrumentwhichmustbehandledwithcare.Priortoeachcanningseasonorbeforethenextuse,ifthe
cover has been submerged in water, dropped, the gauge glass has broken or fallen out, any parts are rusty, the pointer is not in the
“0” block, or if for any reason you believe the gauge may not be accurate, have the gauge checked for accuracy by your local family
livingagentorextensionhomeeconomist.Ifyouareunabletohaveyourdialgaugecheckedlocally,carefullyremovethegaugeand
sendittothePrestoConsumerServiceDepartment(seepage6).Anaccuratedialgaugeisnecessarytohelppreventfoodspoilage
and possible food poisoning.
6. IfthePressureCannerbecomesdifculttoopenorcloseandthesealingringhasexpanded,replacethesealingringandautomatic
air vent
7. Anymaintenancerequiredfor this product, other than normal household care andcleaning,shouldbeperformedbythe Presto
FactoryServiceDepartment.
Installing the Pressure Dial Gauge
Toinstallthepressuredialgauge,threadthestemofthegaugeintotheCannercover,turningthegaugeclockwiseuntilthedialgaugebase
isushagainstthecover.Stopturningwhenthedialgaugefacesthedirectionyouwant.Note:Models01/CAA12Hand01/CAA20H
are different and install with a nut.
Fig. G