3
GEN-55P GEN-70P
26035 26036
9.3 HP
OHV 4-Cycle
389 cm
3
439 cm
3
Gasoline
Gas Power Generator
6.6 Gallons
10.7 Hp
7.3 Hp
8.8 Hp
94 dB
60 minutes’ rest per tank consumed,
continuously working in rated power.
16 Hp13 Hp
Four 120 V / One 240 V / One 12 V
120 V / 240 V
Carbon Brushes
Carbon Brushes
220 V
110 V
20A
20A
30 A
X
Y
W
G
1
2
3
4
7
5
6
11
9
8
10
12
V
G
L
N
G
L
N
10 A
Winding
Red
Blue Blue
Red
Red
2P Switch
20,8 A
Red
Red 1,0 mm
2
Red 1,0 mm
2
Red
Red
Red
White
White
White
Black
White
White
White White
White
Red 1,0 mm
2
White
Green
Black
Black / White
Green / White
Green / White 1,0 mm
2
Yellow
Black 1,0 mm
2
Black 1,0 mm
2
Black
Winding
Winding
Rotor
Winding
c.c.
Winding
Yellow / Green
2,5 mm
2
White
Black
Black
Oil
Control
Winding
Purple
Purple
Brown
Brown
9 holes male tab.
Rectifier Bridge 10A
Rectifier
Bridge
25 A
Overload Protection 5 A
Oil
Protection
Red
Battery
Black
Spark
Plug
Start Up
Winding
Carburetor
Electromagnet
Charge
Winding
Green / White
1,0 mm
2
Black
Return Route
2,5 mm
2
Black
Relay
Insulator
Fuse
Key
Double Voltage Selector
10,0 mm
2
Motor Start
Rotor
Winding
Carbon Brushes
Carbon Brushes
Red Red
Red
Red
Red 1,0 mm
2
Red 1,0 mm
2
Blue
Switch
30 A
Winding
Winding
Winding
Rectifier
Bridge
25A
c.c.
Winding
Overload Protection 5 A
Black
Black 1,0 mm
2
Black
Black
Yellow / Green
2,5 mm
2
X
Y
W
G
White
White
White White
White
White
White
V
G
L
N
G
L
N
9 holes male tab.
Oil
Control
Winding
Brown
Brown
Rectifier Bridge 10 A
Key
Blue
1P Switch 25 A
Return Route
4,0 mm
2
10 A
Red 1,0 mm
2
White
Green
Black
Black / White
Green / White
Green / White 1,0 mm
2
Yellow
Black
Purple
Purple
Oil
Protection
Red
Battery
Black
Spark
Plug
Start Up
Winding
Carburetor
Electromagnet
Charge
Winding
Green / White
1,0 mm
2
Relay
Fuse
10,0 mm
2
Motor Start
ENGLISH
Technical Data
Fuel Requirements
Electric Diagram
Code
Description
Motor Rated Power
Motor
Cubic Capacity
Fuel
Fuel Tank
Voltage
Load Maximum Output
Output
Rated Output
Noise Level
Work Cycle
• The generator is built with an air-cooled, 4 – stroke motor using unleaded pure gasoline.
• For no reason at all mix oil with the fuel.
• For no reason at all use fuel mixed with ethyl alcohol (gasohol), ethanol, or methane. These attract
humidity causing separation and acid build-up while stored. Acidity may damage the motor fuel system when stored.
• To prevent issues with the motor, empty the fuel system before storing the generator during 30 days or longer
periods of time. Empty the gasoline tank, start the motor and leave it running until the fuel and carburetor lines are
empty. The next season, use fresh gasoline.
• Never pour into the gasoline tank, motor or carburetor cleaning liquids because it can result in permanent damage.
WARNING
GEN-55P GEN-70P