location
INSTALLATlON
The overall height from bottom of fireplace
to
chimney flue outlet is
to
he
not
less than
16
for
Models
81288,
81366
or 12’6” for the
81428
with the
standard chimney termination.
(ERTSA
or IORTSA). If
Decorative Chimney
(DCT)
is used overall height may
be reduced on
81288
and
81368
lo
12’6”.
81288
and
81368
overall height may be reduced
to
11’ by using
a
BFSL
Thimble in place of a fIrestop spacer
at
first
ioist area. Installation may be 90 feet in height but
must be supported
at
every 35 foot level.
Fireplace lwdlion will he influenced by such factors
as traffic in rooms, doors
and
windows and
construe-
tion
above and below the
firepldce.
~irepl~e may be installed in any location which will
provide the necessary clearances. A location that r”-
yuires
cutting the least number of ioists or rafters
WIII
simplify and reduce installation cost. The fireplace
may be installed
directly
on the floor
or
elevated
on
a
wooden or masonry l,Iatform if desired. However. the
floor or platform must be solid and continuous to
prevent any air from entering the room from under
the fireplace. See Page 5 for chase construction.
The fireplace may be positioned and then the fram-
ing built around
it
or
the framing may be constructed
and the fireplace pushed into the opening. (See
Fig. 10.) The dimensions shown on Pages 2 and 3
may
be used
to
construci
the fireplace opening.
CORNER INSTALLATION
This can be the most economical in
rooms
where
wall space is at a premium. Because of the slanted
sides, the fireplace seems to take less area of floor
space than being
proiected
into the
room
from a flat
wall. (See Fig.
5.)
Cross Section
TRIPLE WALL
INSULATION
DAMPER
~~L”L
~T~;l;l”
HANDLE
\
FRAME ‘BOTTOM
INSULATION
ASSEMBLY
PROJECTION
PROJECTION
.
CLEARANCE TO CORNER MUST BE 36”.
IF
WS40 WALL SHIELD IS INSTALLED
*
CAN BE REDUCED TO 12”
Framing Dimensions
CHART 2
Dimensions
28”.
36” 42” Fireplace
Measurement
1
B12BB
1
81368
1
81428
I
A
1
14%” SQ.
1
14%” SQ.
1
16%” SQ.
B
I
7%”
I
7w
I
8%”
H
2%”
2%”
13/4”
J
38”
46”
52”
Y
1
0” 71”
7K*
t
I.
1
,
I
__
I
-_
L
/
49%”
1
55%”
1
59%”
With 8FSL
Firestop
Spacer
at First Joist Area
A
17%” SQ.
17%” SQ.
6
8A”
87@”
H
1
‘/s”
1
vi’
HEARTH
EXTENSION
42”~
16”
52”~
1
6”
66”XzO”
NOTE: Los Angeles code requires Hearth to be
12”
each side of Fireplace
openirng
and 20” deep.