EN
Prexiso P40T
7
Technical Data
*
The typical measurement uncertainty of ± 3 mm
is valid for measurements on white, diffusive,
reflective targets up to 5 m at low ambient light
and moderate temperatures. For distances
greater than 5 m, the measurement uncertainty
could increase additionally by 0.1 mm/m. In
unfavourable conditions (such as bright sunlight,
targets with poor reflectivity, or high or low
temperatures) the measurement uncertainty
could further increase up to ± 8 mm for distances
below 5 m and additionally by roughly 0.15
mm/m for distances greater than 5 m.
Error, faults & troubleshooting Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or
solvents.
Disposal
CAUTION
The battery must not be disposed of
with household waste. Care for the
environment and take them to the
collection points provided in
accordance with national or local
regulations.The product must not be
disposed with household waste.
Dispose of the
product appropriately in
accordance with the national
regulations in force in your country.
Adhere to the national and country
specific regulations. Product specific
treatment and waste management
can be downloaded from our
homepage.
General
Maximum
measuring range*
Measuring accuracy*
Measuring units
Laser class
Laser type
Autom. power switch-off
Autom. laser off
Battery durability
(2 x AAA)
Dimension(LxWxH)
Weight (without batteries)
Operation Temperature
Storage Temperature
1.14-135ft / 0.35-40m
(measure from top side)
± 1/8 in
± 3 mm
ft+inch/m/ft/inch
2
620nm - 690nm
120s
30s
up to 3000
measurements
4.02 x 1.42x0.75 in
102 x 36 x19 mm
1.76oz / 50g
32 to 104 °F
0 to 40 °C
14 to 140 °F
-10 to 60 °C
Potential issue table
ISSUE CAUSE ACTION
Hardware protection
after shocking
Restart the
device
Low battery
Recharge the
device
Failure to
switch on
All dashes shows
on display
Insufficient
On/Measure/Units
button press
Press the
On/Measure/Units
button firmly
Received signal
too weak/
Measuring time too long
Change target surface
(e.g. white paper)
Received signal
too strong
(target is too reflective)
Change target surface
Ambient light
is too strong
Shadow target area
(e.g. white paper)
The object is out
of rated range
Measure within
rated range
Beam is moved too fast
Move the measuring
tool slowly