Technical Data
* Favourable conditions are: white and diffuse
reflecting target (white painted wall), low
background illumination and moderate
temperatures.
** Tolerances apply with a confidence level of
95%.
Message Codes
If the message Error does not disappear after
switching on the device repeatedly, contact the
dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:
Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or
solvents.
Disposal
CAUTION
Flat batteries must not be disposed
of with household waste. Care for
the environment and take them to
the collection points provided in
accordance with national or local
regulations. The product must not
be disposed with household waste.
Dispose of the product
appropriately in accordance with the
national regulations in force in your
country. Adhere to the national and
country specific regulations.Product
specific treatment and waste
management can be downloaded
from our homepage.
Warranty
The Prexiso P70DLI has two-years
warranty.
For further information on this, contact
your dealer. Subject to change (drawings,
descriptions and technical data).
General
Range for one head 0.3 ~ 35 m
0.98 ~ 115 ft
Range for dual head 0.6 ~ 70 m
1.97 ~ 230 ft
Measuring accuracy* one head: ± 3mm(±1/8")
dual head ± 6mm(±1/4")
Smallest unit displayed 1 mm
1/16 in
Laser class
Laser type
Angle range
Angle accuracy
Autom. power switch-off
Continuous measuring
Area / Volume
Dimension (H x D x W)
2
620-690 nm, < 1 mW
-90°-90°
after 120 s
< ±1°
yes
yes
Battery durability (2 x AAA)
up to 3000
measurements
Weight
(without batteries)
Temperature range:
- Storage
- Operation
-10 to 60 °C
14 to 140 °F
0 to 40 °C
32 to 104 °F
120.4 x 36 x 21 mm
4.74 x 1.42 x 0.83 in
59 g / 2.08 oz
No. Cause Correction
255 Received signal too
weak, measuring time
too long or outside of
measuring range
Change target
surface (e.g. white
paper)or correct
range.
301 Trigonometric function
measurement
sequence is wrong
Follow the steps to
measure.
401 Hardware failure or
module measurement
transmission failure
Re-operate or
restart or seek
customer service.
Prexiso P70DLI
8
EN